Rapid Microarray Detection of DNA and Proteins in Microliter Volumes with Surface Plasmon Resonance Imaging Measurements

被引:28
作者
Seefeld, Ting Hu [1 ]
Zhou, Wen-Juan [1 ]
Corn, Robert M. [1 ]
机构
[1] Univ Calif Irvine, Dept Chem, Irvine, CA 92697 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
RNA APTAMER MICROARRAYS; DIFFRACTION GRATINGS; FABRICATION; MICRORNAS; KINETICS; ARRAYS; ADSORPTION; EXPRESSION; BIOMARKERS; DISEASE;
D O I
10.1021/la200649n
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A four-chamber microfluidic biochip is fabricated for the rapid detection of multiple proteins and nucleic acids from microliter volume samples with the technique of surface plasmon resonance imaging (SPRI). The 18 mm x 18 mm biochip consists of four 3 mu L microfluidic chambers attached to an SF10 glass substrate, each of which contains three individually addressable SPRI gold thin film microarray elements. The 12-element (4 x 3) SPRI microarray consists of gold thin film spots (1 mm(2) area; 45 nm thickness), each in individually addressable 0.5 mu L volume microchannels. Microarrays of single-stranded DNA and RNA (ssDNA and ssRNA, respectively) are fabricated by either chemical and/or enzymatic attachment reactions in these microchannels; the SPRI microarrays are then used to detect femtomole amounts (nanomolar concentrations) of DNA and proteins (ssDNA binding protein and thrombin via aptamer-protein bioaffinity interactions). Microarrays of ssRNA microarray elements are also used for the ultrasensitive detection of zeptomole amounts (femtomolar concentrations) of DNA via the technique of RNase H-amplified SPRI. Enzymatic removal of ssRNA from the surface due to the hybridization adsorption of target ssDNA is detected as a reflectivity decrease in the SPR imaging measurements. The observed reflectivity loss is proportional to the log of the target ssDNA concentration with a detection limit of 10 fM or 30 zeptomoles (18 000 molecules). This enzymatic amplified ssDNA detection method is not limited by diffusion of ssDNA to the interface, and thus is extremely fast, requiring only 200 s in the microliter volume format.
引用
收藏
页码:6534 / 6540
页数:7
相关论文
共 45 条
[21]   Enhanced bioaffinity sensing using surface plasmons, surface enzyme reactions, nanoparticles and diffraction gratings [J].
Lee, Hye Jin ;
Wark, Alastair W. ;
Corn, Robert M. .
ANALYST, 2008, 133 (05) :596-601
[22]   Creating advanced multifunctional biosensors with surface enzymatic transformations [J].
Lee, Hye Jin ;
Wark, Alastair W. ;
Corn, Robert M. .
LANGMUIR, 2006, 22 (12) :5241-5250
[23]   Detection of protein biomarkers using RNA aptamer microarrays and enzymatically amplified surface plasmon resonance imaging [J].
Li, Yuan ;
Lee, Hye Jin ;
Corn, Robert M. .
ANALYTICAL CHEMISTRY, 2007, 79 (03) :1082-1088
[24]   Fabrication and characterization of RNA aptamer microarrays for the study of protein-aptamer interactions with SPR imaging [J].
Li, Yuan ;
Lee, Hye Jin ;
Corn, Robert M. .
NUCLEIC ACIDS RESEARCH, 2006, 34 (22) :6416-6424
[25]   Size-dependent DNA mobility in cytoplasm and nucleus [J].
Lukacs, GL ;
Haggie, P ;
Seksek, O ;
Lechardeur, D ;
Freedman, N ;
Verkman, AS .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (03) :1625-1629
[26]  
McDonald JC, 2000, ELECTROPHORESIS, V21, P27, DOI 10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.3.CO
[27]  
2-3
[28]   THE SINGLE-STRANDED DNA-BINDING PROTEIN OF ESCHERICHIA-COLI [J].
MEYER, RR ;
LAINE, PS .
MICROBIOLOGICAL REVIEWS, 1990, 54 (04) :342-380
[29]   Surface plasmon resonance imaging measurements of DNA and RNA hybridization adsorption onto DNA microarrays [J].
Nelson, BP ;
Grimsrud, TE ;
Liles, MR ;
Goodman, RM ;
Corn, RM .
ANALYTICAL CHEMISTRY, 2001, 73 (01) :1-7
[30]   Microarray-based, high-throughput gene expression profiling of microRNAs [J].
Nelson, PT ;
Baldwin, DA ;
Scearce, LM ;
Oberholtzer, JC ;
Tobias, JW ;
Mourelatos, Z .
NATURE METHODS, 2004, 1 (02) :155-161