Stereolithographic models simulating trabecular bones and their characterization by thin-slice- and micro-CT

被引:11
作者
Engelke, K [1 ]
Süss, C [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
bone; structure; phantoms; stereolithography; thin-slice CT; micro-CT;
D O I
10.1007/s003300100927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The analysis of bone structure in vivo is an important goal in osteoporosis, because the determination of bone mineral density alone is insufficient to predict whether an individual patient will eventually suffer an osteoporotic fracture or not. An additional structural analysis may significantly improve the statistical assessment of fracture risk. In this study we present a method to generate realistic although enlarged 3D phantoms of trabecular bone. These phantoms are useful in characterizing the potential of in vivo imaging, procedures for the analysis of bone structure and to verify textural or structural analysis methods applied to these images. Our phantoms are based on a real trabecular bone specimen that was converted to a plastic model using the technique of stereolithography. The trabecular network is modeled by hydroxyapatite. Limitations of the stereolithographic process prevent the generation of exact 1:1 replicas of the real bone. A histomorphometric analysis Of LCT scans of the phantoms showed that an excellent replication of the bone structure could be achieved in phantoms enlarged by a factor of 2.5 with "trabecular" hydroxyapatite concentrations up to 400 mg/cm(3). In order to demonstrate the usefulness of our phantoms, we investigated one of them with various thin-slice CT protocols using clinical single-and multi-slice spiral CT scanners. The enlargement of the phantoms limits their use on high spatial resolution CT scanners (resolution > 20 lp/cm). The limited hydroxyapatite concentration requires enhanced exposure rates for the phantoms scans to offset the larger impact of noise due to the lower contrast in the phantoms.
引用
收藏
页码:2026 / 2040
页数:15
相关论文
共 31 条
[1]  
[Anonymous], 2000, COMPUTED TOMOGRAPHY
[2]   STEREOLITHOGRAPHY IN ORAL AND MAXILLOFACIAL OPERATION PLANNING [J].
BILL, JS ;
REUTHER, JF ;
DITTMANN, W ;
KUBLER, N ;
MEIER, JL ;
PISTNER, H ;
WITTENBERG, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (01) :98-103
[3]   CT IMAGE-ANALYSIS OF THE VERTEBRAL TRABECULAR NETWORK INVIVO [J].
CHEVALIER, F ;
LAVALJEANTET, AM ;
LAVALJEANTET, M ;
BERGOT, C .
CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) :8-13
[4]   Image analysis of the distal radius trabecular network using computed tomography [J].
Cortet, B ;
Dubois, P ;
Boutry, N ;
Bourel, P ;
Cotten, A ;
Marchandise, X .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (05) :410-419
[5]  
Engelke K, 1998, BONE DENSITOMETRY AND OSTEOPOROSIS, P417
[6]  
Engelke K, 1996, J BONE MINER RES, V11, P480
[7]  
ENGELKE K, 1997, SPIES 42 ANN M SPIE, P53
[8]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[9]  
GEBHARDT A, 1996, RAPID PROTOTYPING WE
[10]   In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images [J].
Gordon, CL ;
Webber, CE ;
Christoforou, N ;
Nahmias, C .
MEDICAL PHYSICS, 1997, 24 (04) :585-593