Stereolithographic models simulating trabecular bones and their characterization by thin-slice- and micro-CT

被引:11
作者
Engelke, K [1 ]
Süss, C [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
bone; structure; phantoms; stereolithography; thin-slice CT; micro-CT;
D O I
10.1007/s003300100927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The analysis of bone structure in vivo is an important goal in osteoporosis, because the determination of bone mineral density alone is insufficient to predict whether an individual patient will eventually suffer an osteoporotic fracture or not. An additional structural analysis may significantly improve the statistical assessment of fracture risk. In this study we present a method to generate realistic although enlarged 3D phantoms of trabecular bone. These phantoms are useful in characterizing the potential of in vivo imaging, procedures for the analysis of bone structure and to verify textural or structural analysis methods applied to these images. Our phantoms are based on a real trabecular bone specimen that was converted to a plastic model using the technique of stereolithography. The trabecular network is modeled by hydroxyapatite. Limitations of the stereolithographic process prevent the generation of exact 1:1 replicas of the real bone. A histomorphometric analysis Of LCT scans of the phantoms showed that an excellent replication of the bone structure could be achieved in phantoms enlarged by a factor of 2.5 with "trabecular" hydroxyapatite concentrations up to 400 mg/cm(3). In order to demonstrate the usefulness of our phantoms, we investigated one of them with various thin-slice CT protocols using clinical single-and multi-slice spiral CT scanners. The enlargement of the phantoms limits their use on high spatial resolution CT scanners (resolution > 20 lp/cm). The limited hydroxyapatite concentration requires enhanced exposure rates for the phantoms scans to offset the larger impact of noise due to the lower contrast in the phantoms.
引用
收藏
页码:2026 / 2040
页数:15
相关论文
共 31 条
[21]   Assessment of trabecular structure using high resolution CT images and texture analysis [J].
Link, TM ;
Majumdar, S ;
Lin, JC ;
Augat, P ;
Gould, RG ;
Newitt, D ;
Ouyang, XL ;
Lang, TF ;
Mathur, A ;
Genant, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (01) :15-24
[22]   A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT [J].
Link, TM ;
Majumdar, S ;
Lin, JC ;
Newitt, D ;
Augat, P ;
Ouyang, XL ;
Mathur, A ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (01) :122-132
[23]   Imaging of trabecular bone structure in osteoporosis [J].
Link, TM ;
Majumdar, S ;
Grampp, S ;
Guglielmi, G ;
van Kuijk, C ;
Imhof, H ;
Glueer, C ;
Adams, JE .
EUROPEAN RADIOLOGY, 1999, 9 (09) :1781-1788
[24]  
LOPPONEN H, 1999, ACTA OTOLARYNGOL S, V529, P47
[25]   Trabecular bone architecture in the distal radius using magnetic resonance imaging in subjects with fractures of the proximal femur [J].
Majumdar, S ;
Link, TM ;
Augat, P ;
Lin, JC ;
Newitt, D ;
Lane, NE ;
Genant, HK .
OSTEOPOROSIS INTERNATIONAL, 1999, 10 (03) :231-239
[26]   High resolution magnetic resonance imaging of trabecular structure [J].
Majumdar, S ;
Genant, HK .
EUROPEAN RADIOLOGY, 1997, 7 (Suppl 2) :S51-S55
[27]  
McGurk M, 1997, ANN ROY COLL SURG, V79, P169
[28]   Morphometric analysis of noninvasively assessed bone biopsies: Comparison of high-resolution computed tomography and histologic sections [J].
Muller, R ;
Hahn, M ;
Vogel, M ;
Delling, G ;
Ruegsegger, P .
BONE, 1996, 18 (03) :215-220
[29]  
Muller R, 1996, J BONE MINER RES, V11, P1745
[30]   Rapid prototyping technology in medicine - basics and applications [J].
Petzold, R ;
Zeilhofer, HF ;
Kalender, WA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (05) :277-284