Quantitative bone mineral assessment at the forearm: A review

被引:94
作者
Augat, P [1 ]
Fuerst, T [1 ]
Genant, HK [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, Osteoporosis & Arthrit Res Grp, San Francisco, CA 94143 USA
关键词
bone mineral density; distal radius; dual X-ray absorptiometry (DXA); osteoporosis; peripheral quantitative computed tomography (pQCT);
D O I
10.1007/s001980050068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone mineral density and geometric properties of the human forearm can be measured to determine the amount of bone or bone loss at the scanning site and to predict the risk of forearm fractures. These forearm measurements are also used to estimate bone mass at remote anatomical locations and thereby estimate the risk for spine, hip and other fractures. The peripheral location of the human forearm, with its relatively small amount of surrounding soft tissue, improves the accuracy and the precision of bone mass measurement and has made this site an early choice for the assessment of a subject's bone mineral status. Furthermore, the anatomy of the human radius enables the examination of both cortical and cancellous bone. This review describes the procedures for non-invasive bone assessment at peripheral sites including some of the more recently developed systems dedicated to assessment of the distal radius. The accuracy, precision and normative values they provide are presented. Responses to different forms of therapies as well as the ability to discriminate or predict osteoporotic fractures are also assessed. Low radiation dose, comfortable and fast handling, moderate cost, and a strong association with the risk of non-spine fractures, promote the use of forearm scanning as a widely applied screening procedure for the detection of generalised osteoporotic bone loss. However, a higher accuracy of fracture risk prediction at the spine or at the hip can be achieved by a direct bone density measurement at these sites. The monitoring of treatment at the distal forearm appears to require a longer follow-up time due to its decreased responsiveness compared with such highly trabecular load-bearing sites as the spine and the proximal femur.
引用
收藏
页码:299 / 310
页数:12
相关论文
共 131 条
[31]   IMPACT OF MARROW FAT ON ACCURACY OF QUANTITATIVE CT [J].
GLUER, CC ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) :1023-1035
[32]   BONE MINERAL IN RADIUS AND VERTEBRAL OSTEOPOROSIS IN AN INSURED POPULATION - CORRELATIVE STUDY USING I-125 PHOTON ABSORPTION AND MINIATURE ROENTGENOGRAPHY [J].
GOLDSMITH, NF ;
JOHNSTON, JO ;
PICETTI, G ;
CARCIA, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (06) :1276-1293
[33]   In vivo assessment of trabecular bone structure at the distal radius from high-resolution computed tomography images [J].
Gordon, CL ;
Webber, CE ;
Adachi, JD ;
Christoforou, N .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) :495-508
[34]  
GRAMPP S, 1995, J BONE MINER RES, V10, P1566
[35]   CURRENT STATUS OF PHYSICAL MEASUREMENTS OF THE SKELETON [J].
GREENFIELD, MA .
MEDICAL PHYSICS, 1992, 19 (06) :1349-1357
[36]  
HAGIWARA S, 1994, J BONE MINER RES, V9, P1425
[37]   SKELETAL CHALLENGE - AN EXPERIMENTAL-STUDY OF PHARMACOLOGICALLY INDUCED CHANGES IN BONE-DENSITY IN THE DISTAL RADIUS, USING GAMMA-RAY COMPUTED-TOMOGRAPHY [J].
HANGARTNER, TN ;
OVERTON, TR ;
HARLEY, CH ;
VANDENBERG, L ;
CROCKFORD, PM .
CALCIFIED TISSUE INTERNATIONAL, 1985, 37 (01) :19-24
[38]   THE OSTEOQUANT - AN ISOTOPE-BASED CT SCANNER FOR PRECISE MEASUREMENT OF BONE-DENSITY [J].
HANGARTNER, TN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (05) :798-805
[39]   BONE MASS MEASURED BY PHOTON-ABSORPTIOMETRY - COMPARISON OF FOREARM, HEEL, AND SPINE [J].
HANSEN, MA ;
RIIS, BJ ;
OVERGAARD, K ;
HASSAGER, C ;
CHRISTIANSEN, C .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (05) :517-523
[40]   MEASUREMENT OF THE SUBCUTANEOUS FAT IN THE DISTAL FOREARM BY SINGLE PHOTON-ABSORPTIOMETRY [J].
HASSAGER, C ;
BORG, J ;
CHRISTIANSEN, C .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1989, 38 (02) :159-165