New concept in echocardiography:: harmonic imaging of tissue without use of contrast agent

被引:113
作者
Caidahl, K [1 ]
Kazzam, E
Lidberg, J
Andersen, GN
Nordanstig, J
Dahlwvist, SR
Waldenström, A
Wikh, R
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
[2] Univ Umea Hosp, Dept Cardiol, S-90185 Umea, Sweden
[3] Univ Umea Hosp, Dept Rheumatol, S-90185 Umea, Sweden
关键词
D O I
10.1016/S0140-6736(98)02361-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Endocardial border detection is important for echocardiographic assessment of left-ventricular function. Second harmonic imaging of contrast agents enhances this border detection. We discovered that harmonic imaging improves tissue visualisation even before contrast injection. We therefore sought objectively to demonstrate the degree of enhancement of endocardial and myocardial visualisation. Methods An ATL HDI-3000 scanner with software for contrast harmonic imaging was used to record short-axis images of the left ventricle in 27 patients with possible myocardial disease and 22 controls, in the fundamental mode and with harmonic imaging. A computer program measured the relative grey-scale values within six segments of the endocardium and myocardium. An Acuson Sequoia Scanner equipped with software for tissue harmonic imaging was used to investigate the reproducibility of ejection-fraction calculations in 22 patients with ischaemic heart disease. Findings Harmonic imaging produced brighter endocardium within each segment. Relative to the mean grey value of the total imaging sector, the values for harmonic and fundamental imaging were 171.5 vs 85.6% (p<0.0001) in end diastole and 194.1 vs 106.7% (p<0.0001) in end systole. Results for the myocardial segments were also significantly better for harmonic imaging. Structure enhancement of similar magnitude was seen among patients and healthy controls. Use of harmonic imaging reduced the proportion of unacceptable images by 14-46% in different views and improved the reproducibility of biplane ejection-fraction measurements. Interpretation In comparison with fundamental imaging, the relative endocardial and myocardial brightness is enhanced by harmonic imaging.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 19 条
[1]  
AVERKIOU M, 1997, IEEE ULTR S TOR ONT, P1561
[2]   Prolonged myocardial contrast echocardiography via peripheral venous administration of QW3600 injection (EchoGen(R)): Its efficacy and side effects [J].
Beppu, S ;
Matsuda, H ;
Shishido, T ;
Matsumura, M ;
Kiyatake, K .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (01) :11-24
[3]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[4]   ATTENUATION OF LEFT-VENTRICULAR DILATATION AFTER ACUTE MYOCARDIAL-INFARCTION BY EARLY INITIATION OF ENALAPRIL THERAPY [J].
BONARJEE, VVS ;
CARSTENSEN, S ;
CAIDAHL, K ;
NILSEN, DWT ;
EDNER, M ;
BERNING, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (14) :1004-1009
[5]  
CAIDAHL K, 1997, EUR HEART J SUPPL, V19, P146
[6]   Benefits of reducing the cardiac cycle-triggering frequency of ultrasound imaging to increase myocardial opacification with FSO69 during fundamental and second harmonic imaging [J].
Colon, PJ ;
Richards, DR ;
Moreno, CA ;
Murgo, JP ;
Cheirif, J .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (06) :602-607
[7]   On the feasibility of real time, in vivo harmonic imaging with proteinaceous microspheres [J].
Forsberg, F ;
Goldberg, BB ;
Liu, JB ;
Merton, DA ;
Rawool, NM .
JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (12) :853-860
[8]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ECHO CONTRAST AGENT IN ECHOCARDIOGRAPHIC STUDIES IN PATIENTS [J].
GENY, B ;
METTAUER, B ;
MUAN, B ;
BISCHOFF, P ;
EPAILLY, E ;
PIQUARD, F ;
EISENMANN, B ;
HABEREY, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1193-1198
[9]  
GUSTAFSSON R, 1989, LANCET, V2, P475
[10]  
Iliceto S, 1996, EUR HEART J, V17, P344