Biomimetic sensors of molecularly-imprinted polymers for chlorpromazine determination

被引:27
作者
Moreira, Felismina T. C. [1 ]
Sales, M. Goreti F. [1 ]
机构
[1] Inst Super Engn Porto, REQUIMTE, P-4200072 Oporto, Portugal
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2011年 / 31卷 / 05期
关键词
Chlorpromazine; Molecularly-imprinted sensors; Potentiometry; FIA; Fish; SUBSTITUTED PHENOTHIAZINE-DERIVATIVES; FLOW-INJECTION CHEMILUMINESCENCE; ION-SELECTIVE ELECTRODES; SOLID-PHASE EXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; PROMETHAZINE HYDROCHLORIDE; PHARMACEUTICAL ANALYSIS; POTENTIOMETRIC SENSORS; LIQUID-CHROMATOGRAPHY; HUMAN SERUM;
D O I
10.1016/j.msec.2011.04.012
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
082905 [生物质能源与材料]; 100103 [病原生物学];
摘要
A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51-67 mV/decade and 0.46-3.9 mu g/ml, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0-5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 x 10(-2) mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 x 10(-4) to 1.0 X 10(-2) mol/L Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1121 / 1128
页数:8
相关论文
共 66 条
[1]
Determination of five phenothiazines in pure and pharmaceutical preparations using vanadium pentoxide as a chromogenic reagent [J].
Aman, T ;
Anwar, J ;
Ahmad, A ;
Latif, L .
ANALYTICAL LETTERS, 2003, 36 (14) :2961-2974
[2]
Molecularly imprinted solid-phase extraction of diazepam and its metabolites from hair samples [J].
Ariffin, Marinah M. ;
Miller, Eleanor I. ;
Cormack, Peter A. G. ;
Anderson, Robert A. .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :256-262
[3]
Basavaiah K, 2005, INDIAN J CHEM TECHN, V12, P25
[4]
Basavaiah K, 2004, INDIAN J CHEM TECHN, V11, P11
[5]
Differential-pulse polarographic determination of some N-substituted phenothiazine derivatives in dosage forms and urine through treatment with nitrous acid [J].
Belal, F ;
El-Ashry, SM ;
Shehata, IM ;
El-Sherbeny, MA ;
El-Sherbeny, DT .
MIKROCHIMICA ACTA, 2000, 135 (3-4) :147-154
[6]
Electrochemical sensors based on molecularly imprinted polymers [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (01) :36-48
[7]
An innovative approach to the design of plastic antibodies: molecular imprinting via a non-polar transition state analogue [J].
Busi, E ;
Basosi, R ;
Ponticelli, F ;
Olivucci, M .
JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2004, 217 (1-2) :31-36
[8]
Heavy use of prophylactic antibiotics in aquaculture: a growing problem for human and animal health and for the environment [J].
Cabello, Felipe C. .
ENVIRONMENTAL MICROBIOLOGY, 2006, 8 (07) :1137-1144
[9]
Sol-gel-immobilized Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography [J].
Choi, HN ;
Cho, SH ;
Park, YJ ;
Lee, DW ;
Lee, WY .
ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) :49-56
[10]
RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58