Long-Term Results of Third-Generation Ceramic-on-Ceramic Bearing Cementless Total Hip Arthroplasty in Young Patients

被引:35
作者
Kim, Young-Hoo [1 ]
Park, Jang-Won [2 ]
Kim, Jun-Shik [2 ]
机构
[1] Ewha Womans Univ, Sch Med, SeoNam Hosp, Ctr Joint Replacement, Seoul, South Korea
[2] Ewha Womans Univ, Sch Med, MokDong Hosp, Ctr Joint Replacement, Seoul, South Korea
关键词
third generation of ceramic-on-ceramic; bearing; total hip arthroplasty; osteolysis; survivorship; aseptic loosening; ceramic fracture; 12-YEAR FOLLOW-UP; REPLACEMENT; POLYETHYLENE; OSTEOLYSIS; COMPONENT; MINIMUM; HEAD; THA; AGE;
D O I
10.1016/j.arth.2016.03.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The results of third-generation of alumina-on-alumina ceramic bearing in a large number of patient cohorts are limited. The purpose of this study was to determine clinical and radiologic outcome, prevalence of osteolysis detected with radiographs and computerized tomographic scan, and survivorship of a cementless total hip arthroplasty using a third-generation of alumina-on-alumina ceramic bearing in a large number of active patients aged younger than 65 years. Methods: We reviewed the cases of 871 patients (1131 hips) who underwent a cementless total hip arthroplasty when they were aged 65 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (53%) and osteoarthritis (20%). Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. The mean follow-up interval was 18.8 years (range, 15-20 years). Results: At the time of final follow-up, the mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 90 points, 15 points, and 8 points, respectively. All the femoral stem and acetabular components were well-fixed at the time of final follow-up. No hip had aseptic loosening or osteolysis or fracture of ceramic material at the time of the final follow-up. Conclusion: The current results with the use of the third-generation of alumina-on-alumina ceramic bearings in young patients suggest that cementless acetabular and femoral components provide outstanding long-term fixation and provide a high rate of survivorship without evidence of osteolysis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2520 / 2524
页数:5
相关论文
共 31 条
[1]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[2]
Ceramic-on-ceramic bearings in total hip arthroplasty [J].
Bierbaum, BE ;
Nairus, J ;
Kuesis, D ;
Morrison, JC ;
Ward, D .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :158-163
[3]
Bizot P, 2000, J Orthop Sci, V5, P622, DOI 10.1007/s007760070017
[4]
Computed tomography to assess pelvic lysis after total hip replacement [J].
Claus, AM ;
Totterman, SM ;
Sychterz, CJ ;
Tamez-Peña, JG ;
Looney, RJ ;
Engh, CA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (422) :167-174
[5]
Radiographic definition of pelvic osteolysis following total hip arthroplasty [J].
Claus, AM ;
Engh, CA ;
Sychterz, CJ ;
Xenos, JS ;
Orishimo, KF ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (08) :1519-1526
[6]
Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years [J].
D'Antonio, James A. ;
Capello, William N. ;
Naughton, Marybeth .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :373-381
[7]
Dorr L., 1986, TECH ORTHOP, V1, P22, DOI [10.1097/00013611-198610000-00007, DOI 10.1097/00013611-198610000-00007]
[8]
ENGH CA, 1988, CLIN ORTHOP RELAT R, P7
[9]
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
[10]
Alumina-on-alumina total hip arthroplasty - A minimum 18.5-year follow-up study [J].
Hamadouche, M ;
Boutin, P ;
Daussange, J ;
Bolander, ME ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :69-77