Accuracy and reproducibility of a quantitative magnetic resonance imaging method for concurrent measurements of tissue relaxation times and proton density

被引:101
作者
Krauss, Wolfgang [1 ]
Gunnarsson, Martin [2 ,3 ]
Andersson, Torbjorn [3 ]
Thunberg, Per [3 ,4 ]
机构
[1] Univ Orebro, Fac Med & Hlth, Dept Radiol, S-31705 Orebro, Sweden
[2] Univ Orebro, Fac Med & Hlth, Dept Neurol & Neurophysiol, S-31705 Orebro, Sweden
[3] Univ Orebro, Fac Med & Hlth, S-31705 Orebro, Sweden
[4] Univ Orebro, Fac Med & Hlth, Dept Med Phys, S-31705 Orebro, Sweden
关键词
Quantitative MRI; Synthetic MRI; T1; mapping; T2; PD mapping; Multiple sclerosis; INVERSION-RECOVERY TRUEFISP; MULTIPLE-SCLEROSIS; WHITE-MATTER; IR-TRUEFISP; BRAIN; T-1; T1; QUANTIFICATION; MRI; MS;
D O I
10.1016/j.mri.2015.02.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To evaluate the accuracy and reproducibility of a quantitative magnetic resonance (qMR) imaging method (QRAPMASTER) for simultaneous measurements of T1 and T2 relaxation times, and proton density (PD). Materials and Methods: Measurements of T1, T2, and PD with qMR were performed using phantoms with different relaxation times and concentrations of heavy water. Healthy volunteers were examined with different head coils. Regional measurements were performed in normal-appearing white and gray matter from the healthy control subjects, and in multiple sclerosis (MS) patients. Results: In phantom measurements, QRAPMASTER slightly underestimated T1, and T2 variations between repeated measurements were modest. PD was generally overestimated. The overall relative difference was 1.2 5.3% (T1), 6.6 1.9% (12), and 0.7 5.1% (PD). In healthy volunteers, there were no statistically significant differences of T1, T2 or PD using different head coils. Values of T1, T2, and PD obtained in healthy controls and MS patients were within reference ranges. However, significant differences were found in normal-appearing gray and white matter. Conclusion: QRAPMASTER can be considered a sufficiently accurate and reproducible method for use in clinical practice. Neuropathology in normal-appearing brain tissue may be revealed using this MR method, with putative implications for quantification of tissue damage in neurological diseases. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:584 / 591
页数:8
相关论文
共 36 条
[1]
Evaluation of Automatic Measurement of the Intracranial Volume Based on Quantitative MR Imaging [J].
Ambarki, K. ;
Lindqvist, T. ;
Wahlin, A. ;
Petterson, E. ;
Warntjes, M. J. B. ;
Birgander, R. ;
Malm, J. ;
Eklund, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (10) :1951-1956
[2]
T2 relaxometry of the hippocampus at 3T [J].
Bartlett, P. A. ;
Symms, M. R. ;
Free, S. L. ;
Duncan, J. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (06) :1095-1098
[3]
T1 and proton density at 7 T in patients with multiple sclerosis: an initial study [J].
Bluestein, Katharine T. ;
Pitt, David ;
Knopp, Michael V. ;
Schmalbrock, Petra .
MAGNETIC RESONANCE IMAGING, 2012, 30 (01) :19-25
[4]
Synthetic MRI of the brain in a clinical setting [J].
Blystad, I. ;
Warntjes, J. B. M. ;
Smedby, O. ;
Landtblom, A-M ;
Lundberg, P. ;
Larsson, E-M .
ACTA RADIOLOGICA, 2012, 53 (10) :1158-1163
[5]
Fast Monitoring of T1, T2, and Relative Proton Density (M0) Changes in Skeletal Muscles Using an IR-TrueFISP Sequence [J].
de Sousa, Paulo Loureiro ;
Vignaud, Alexandre ;
Fleury, Servanne ;
Carlier, Pierre G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :921-930
[6]
High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2 [J].
Deoni, SCL ;
Peters, TM ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :237-241
[7]
IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density [J].
Ehses, Philipp ;
Seiberlich, Nicole ;
Ma, Dan ;
Breuer, Felix A. ;
Jakob, Peter M. ;
Griswold, Mark A. ;
Gulani, Vikas .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) :71-81
[8]
Clinical use of brain volumetry [J].
Giorgio, Antonio ;
De Stefano, Nicola .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) :1-+
[9]
Multiple sclerosis: Hyperintense lesions in the brain on nonenhanced T1-weighted MR images evidenced as areas of T1 shortening [J].
Janardhan, Vallabh ;
Suri, Sonu ;
Bakshi, Rohit .
RADIOLOGY, 2007, 244 (03) :823-831
[10]
KURTZKE JF, 1983, NEUROLOGY, V33, P1444, DOI 10.1212/WNL.33.11.1444