Multisection CT: Scanning techniques and clinical applications

被引:227
作者
Rydberg, J [1 ]
Buckwalter, KA [1 ]
Caldemeyer, KS [1 ]
Phillips, MD [1 ]
Conces, DJ [1 ]
Aisen, AM [1 ]
Persohn, SA [1 ]
Kopecky, KK [1 ]
机构
[1] Indiana Univ Hosp, Dept Radiol, Indianapolis, IN 46202 USA
关键词
computed tomography; helical; technology; thin-section;
D O I
10.1148/radiographics.20.6.g00nv071787
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section-capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.
引用
收藏
页码:1787 / 1806
页数:20
相关论文
共 4 条
[1]   Temporal bone: Comparison of isotropic helical CT and conventional direct axial and coronal CT [J].
Caldemeyer, KS ;
Sandrasegaran, K ;
Shinaver, CN ;
Mathews, VP ;
Smith, RR ;
Kopecky, KK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1675-1682
[2]   Subsecond multi-slice computed tomography: basics and applications [J].
Klingenbeck-Regn, K ;
Schaller, S ;
Flohr, T ;
Ohnesorge, B ;
Kopp, AF ;
Baum, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :110-124
[3]   Performance evaluation of a multi-slice CT system [J].
McCollough, CH ;
Zink, FE .
MEDICAL PHYSICS, 1999, 26 (11) :2223-2230
[4]   Are Greek letter social organizations a factor in undergraduates' perceptions of international instructors? [J].
Rubin, DL ;
Ainsworth, S ;
Cho, E ;
Turk, D ;
Winn, L .
INTERNATIONAL JOURNAL OF INTERCULTURAL RELATIONS, 1999, 23 (01) :1-12