Isolation and morphological characterisation of UHMWPE wear debris generated in vitro

被引:51
作者
Affatato, S
Fernandes, B
Tucci, A
Esposito, L
Toni, A
机构
[1] Ist Ortopedici Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Pontifical Catholic Univ Parana, Dept Mech Engn, Parana, Brazil
[3] Italian Ceram Ctr, I-40138 Bologna, Italy
[4] Ist Ortopedici Rizzoli, Div Ortopedia & Traumatol 1, Bologna, Italy
关键词
polyethylene wear debris; hip joint simulator; zirconia-based ceramics; polyethylene debris isolation;
D O I
10.1016/S0142-9612(00)00403-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Wear tests are generally carried out on materials used in prosthetic hip implants, in order to obtain a better understanding of the tribological processes involved and improve the quality control of joint prostheses, directed towards reducing the risk of implant failure of innovative prostheses. Ceramic femoral heads of mixed alumina-zirconia oxides as well as zirconia and alumina single oxide heads were tested against UHMWPE acetabular cups in a hip joint simulator. Polyethylene cups and ceramic femoral heads were mounted in a simulator apparatus moving according to a sinusoidal function, under load and in the presence of bovine calf serum as lubricant. Wear particles were isolated from the bovine calf serum collected during the wear tests. An easy to follow method was used to separate the wear particles from the lubricant. Chemical digestive methods were used to separate the wear particles from the lubricant and the isolated particles were studied using scanning electron microscopy. The morphologies of the polyethylene debris showed considerable differences, both in size and shape of the particles, as a function of the coupled head material. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2325 / 2331
页数:7
相关论文
共 30 条
[1]
Mixed oxides prosthetic ceramic ball heads.: Part 1:: effect of the ZrO2 fraction on the wear of ceramic on polyethylene joints [J].
Affatato, S ;
Testoni, M ;
Cacciari, GL ;
Toni, A .
BIOMATERIALS, 1999, 20 (10) :971-975
[2]
Mixed oxides prosthetic ceramic ball heads.: Part 3:: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses.: A long-term in vitro wear study [J].
Affatato, S ;
Goldoni, M ;
Testoni, M ;
Toni, A .
BIOMATERIALS, 2001, 22 (07) :717-723
[3]
Preparation and properties of binary oxide bioceramics [J].
Agathopoulos, S ;
Nikolopoulos, P ;
Salomoni, A ;
Tucci, A ;
Stamenkovic, I .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (10) :629-636
[4]
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[5]
[Anonymous], 1996, 72062 ISO
[6]
Brummitt K, 1996, Proc Inst Mech Eng H, V210, P187, DOI 10.1243/PIME_PROC_1996_210_411_02
[7]
TISSUE DIGESTION FOR WEAR DEBRIS PARTICLE ISOLATION [J].
CAMPBELL, P ;
MA, S ;
SCHMALZRIED, T ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (04) :523-526
[8]
Campbell P, 1996, Proc Inst Mech Eng H, V210, P167, DOI 10.1243/PIME_PROC_1996_210_409_02
[9]
ISOLATION OF PREDOMINANTLY SUBMICRON-SIZED UHMWPE WEAR PARTICLES FROM PERIPROSTHETIC TISSUES [J].
CAMPBELL, P ;
MA, S ;
YEOM, B ;
MCKELLOP, H ;
SCHMALZRIED, TP ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :127-131
[10]
Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear [J].
Clarke, IC ;
Good, V ;
Anissian, L ;
Gustafson, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :25-36