The pulse oximeter has become an essential tool in the modern practice of emergency medicine, However, despite the reliance placed on the information this monitor offers, the underlying principles and associated limitations of pulse oximetry are poorly understood by medical practitioners. This article reviews the principles of pulse oximetry, with an eye toward recognizing the limitations of this tool. Among these are performance limitations in the settings of carboxyhemoglobinemia, methemoglobinemia, motion artifact, hypotension, vasoconstriction, and anemia, The accuracy of pulse oximetry is discussed in light of these factors, with further discussion of applications for pulse oximetry in emergency medicine, including both oximetric and plethysmographic operation, The pulse oximeter is an invaluable instrument for emergency medicine practice, but as with any test the data it offers must be critically appraised for proper interpretation and utilization. Copyright (C) 1999 by W,B, Saunders Company.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 76 条
[1]  
Anderson J V, 1987, J Perinatol, V7, P323
[2]   BENZOCAINE-INDUCED METHEMOGLOBINEMIA IN AN ADULT - ACCURACY OF PULSE OXIMETRY WITH METHEMOGLOBINEMIA [J].
ANDERSON, ST ;
HAJDUCZEK, J ;
BARKER, SJ .
ANESTHESIA AND ANALGESIA, 1988, 67 (11) :1099-1101
[3]   THE EFFECT OF CARBON-MONOXIDE INHALATION ON PULSE OXIMETRY AND TRANS-CUTANEOUS PO2 [J].
BARKER, SJ ;
TREMPER, KK .
ANESTHESIOLOGY, 1987, 66 (05) :677-679
[4]   THE EFFECT OF SENSOR MALPOSITIONING ON PULSE OXIMETER ACCURACY DURING HYPOXEMIA [J].
BARKER, SJ ;
HYATT, J ;
SHAH, NK ;
KAO, YJ .
ANESTHESIOLOGY, 1993, 79 (02) :248-254
[5]   EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY [J].
BARKER, SJ ;
TREMPER, KK ;
HYATT, J .
ANESTHESIOLOGY, 1989, 70 (01) :112-117
[6]  
BEALL SN, 1989, ANESTH ANALG, V68, P806
[7]  
BOURKE DL, 1991, ANESTH ANALG, V73, P815
[8]   THE PULSE OXIMETRY GAP IN CARBON-MONOXIDE INTOXICATION [J].
BUCKLEY, RG ;
AKS, SE ;
ESHOM, JL ;
RYDMAN, R ;
SCHAIDER, J ;
SHAYNE, P .
ANNALS OF EMERGENCY MEDICINE, 1994, 24 (02) :252-255
[9]   AGREEMENT BETWEEN NONINVASIVE OXIMETRIC VALUES FOR OXYGEN-SATURATION [J].
CAHAN, C ;
DECKER, MJ ;
HOEKJE, PL ;
STROHL, KP .
CHEST, 1990, 97 (04) :814-819
[10]   CAN PULSE OXIMETRY BE USED TO MEASURE SYSTOLIC BLOOD-PRESSURE [J].
CHAWLA, R ;
KUMARVEL, V ;
GIRDHAR, KK ;
SETHI, AK ;
INDRAYAN, A ;
BHATTACHARYA, A .
ANESTHESIA AND ANALGESIA, 1992, 74 (02) :196-200