Treatment of diffuse in-scent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon

被引:46
作者
Park, SW
Hong, MK
Moon, DH
Oh, SJ
Lee, CW
Kim, JJ
Park, SJ
机构
[1] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr,Songpa Gu, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Dept Nucl Med, Asan Med Ctr,Songpa Gu, Seoul 138736, South Korea
关键词
D O I
10.1016/S0735-1097(01)01446-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was done to evaluate the feasibility and efficacy of beta-radiation therapy with a rhenium-188-mercaptoacetyltriglycine (Re-188-MAG(3))-filled balloon after rotational atherectomy for diffuse in-stent restenosis (ISR). BACKGROUND Rotational atherectomy has been shown to be safe and efficient for the treatment of ISR, but the recurrence rate is still high. Intracoronary beta-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent ISR. METHODS Fifty consecutive patients with diffuse ISR (length > 10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty, followed by beta-irradiation using a Re-188-MAG(3) filled balloon catheter. The radiation dose was 15 Gy at a depth of 1.0 mm into the vessel wall. RESULTS The mean lengths of the lesion and irradiated segment were 25.6 +/- 12.7 mm and 37.6 +/- 11.2 mm, respectively. Radiation was delivered successfully to all patients, with a mean irradiation time of 201.8 +/- 61.7 s. No adverse event, including myocardial infarction, death or stent thrombosis, occurred during the follow-up period (mean 10.3 +/- 3.7 months), and nontarget vessel revascularization was needed in one patient. The six-month binary angiographic restenosis rate was 10.4%, and the loss index was 0.17 +/- 0.31. CONCLUSIONS Beta-irradiation using Re-188-MAG(3) filled balloon after rotational atherectomy is safe and feasible in patients with diffuse ISR, and it may improve their clinical and angiographic outcomes. Further prospective, randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR. (C) 2001 by the American College of Cardiology.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 23 条
[1]   Edge restenosis after implantation of high activity 32P radioactive β-emitting stents [J].
Albiero, R ;
Nishida, T ;
Adamian, M ;
Amato, A ;
Vaghetti, M ;
Corvaja, N ;
Di Mario, C ;
Colombo, A .
CIRCULATION, 2000, 101 (21) :2454-2457
[2]   Intracoronary radiation for prevention of restenosis - Dose perturbations caused by stents [J].
Amols, HI ;
Trichter, F ;
Weinberger, J .
CIRCULATION, 1998, 98 (19) :2024-2029
[3]   Dosimetry of a radioactive coronary balloon dilitation catheter for treatment of neointimal hyperplasia [J].
Amols, HI ;
Reinstein, LE ;
Weinberger, J .
MEDICAL PHYSICS, 1996, 23 (10) :1783-1788
[4]   Serial volumetric intravascular ultrasound analysis of the efficacy at beta irradiation in preventing recurrent in-stent restenosis [J].
Bhargava, B ;
Mintz, GS ;
Mehran, R ;
Lansky, AJ ;
Weissman, NJ ;
Walsh, C ;
Chan, RC ;
Waksman, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (05) :651-+
[5]   Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis [J].
Dauerman, HL ;
Baim, DS ;
Cutlip, D ;
Sparano, AM ;
Gibson, CM ;
Kuntz, RE ;
Carrozza, JP ;
Garber, GR ;
Cohen, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :277-284
[6]   The effect of contrast medium and balloon shape on dosimetry for arterial irradiation with 188Re [J].
Fox, RA ;
Henson, PW .
MEDICAL PHYSICS, 1999, 26 (05) :771-776
[7]   Intracoronary β-irradiation with a liquid 188Re-filled balloon -: Six-month results from a clinical safety and feasibility study [J].
Höher, M ;
Wöhrle, J ;
Wohlfrom, M ;
Hanke, H ;
Voisard, R ;
Osterhues, HH ;
Kochs, M ;
Reske, SN ;
Hombach, V ;
Kotzerke, J .
CIRCULATION, 2000, 101 (20) :2355-2360
[8]   Immediate and long-term outcomes of rotational atherectomy versus balloon angioplasty alone for treatment of diffuse in-stent restenosis [J].
Lee, SG ;
Lee, CW ;
Cheong, SS ;
Hong, MK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (02) :140-143
[9]   Evaluation of three rhenium-188 candidates for intravascular radiation therapy with liquid-filled balloons to prevent restenosis [J].
Lin, WY ;
Tsai, SC ;
Hsieh, BT ;
Lee, TW ;
Ting, G ;
Wang, SJ .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (01) :37-42
[10]   Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy - Comparative mechanisms and results [J].
Mehran, R ;
Dangas, G ;
Mintz, GS ;
Waksman, R ;
Abizaid, A ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Lansky, AJ ;
Stone, GW ;
Leon, MB .
CIRCULATION, 2000, 101 (21) :2484-2489