The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators

被引:39
作者
Best, PJM [1 ]
Hayes, DL [1 ]
Stanton, MS [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis, Rochester, MN 55905 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 01期
关键词
dual chamber pacing; implantable cardioverter defibrillators; atrial fibrillation; congestive heart failure;
D O I
10.1111/j.1540-8159.1999.tb00303.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bradycardia support by ICDs has been limited to fixed rate, ventricular pacing. Concomitant placement of a pacemaker and an ICD exposes a patient to potentially life-threatening device interactions. ICDs capable of dual chamber pacing have recently become available. The number of ICD recipients who stand to benefit from the addition of dual chamber pacing is debated, but no data have addressed this question. This retrospective study analyzed all patients who received nonthoractomy ICD system placement at the Mayo Clinic in Rochester, MN between March 1991 and October 1996 in order to determine the proportion of patients in whom a dual chamber pacing ICD may be indicated. Definitions: (1) Definitely indicated. = pacemaker present at ICD implant or NASPE Class I pacing indication; (2) Probably indicated = NASPE Class II pacing indication, NYHA Functional Class III or IV, or history of systolic congestive heart failure; (3) Possibly indicated = history of paroxysmal atrial fibrillation or an ejection fraction less than or equal to 20%. The results were that nonthoracotomy ICDs were placed in 253 patients. A dual chamber ICD would have been definitely indicated in 11% of the study group, probably indicated in 28%, and possibly indicated in 14%. Chronic atrial fibrillation was present at ICD implant in 6.7% of patients and developed in 0.9%/yr during follow-up. The addition of dual chamber pacing to ICDs stands to potentially benefit approximately half (53%) of ICD recipients. These data do not address all patients who may benefit from dual chamber sensing.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 44 条
[31]   MECHANISM OF HEMODYNAMIC IMPROVEMENT BY DUAL-CHAMBER PACING FOR SEVERE LEFT-VENTRICULAR DYSFUNCTION - AN ACUTE DOPPLER AND CATHETERIZATION HEMODYNAMIC-STUDY [J].
NISHIMURA, RA ;
HAYES, DL ;
HOLMES, DR ;
TAJIK, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :281-288
[32]  
PERRINS EJ, 1983, BRIT HEART J, V50, P112
[33]   Problems in managing patients with long QT syndrome and implantable cardioverter defibrillators: A report of two cases [J].
Perry, GY ;
Kosar, EM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (05) :863-867
[34]  
Psaty BM, 1997, CIRCULATION, V96, P2455
[35]   CLINICAL AND HEMODYNAMIC COMPARISON OF VVI VERSUS DDD PACING IN PATIENTS WITH DDD PACEMAKERS [J].
REDIKER, DE ;
EAGLE, KA ;
HOMMA, S ;
GILLAM, LD ;
HARTHORNE, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (04) :323-329
[36]   RISK-FACTORS FOR THE DEVELOPMENT OF RECURRENT ATRIAL-FIBRILLATION - ROLE OF PACING AND CLINICAL-VARIABLES [J].
REIMOLD, SC ;
LAMAS, GA ;
CANTILLON, CO ;
ANTMAN, EM .
AMERICAN HEART JOURNAL, 1995, 129 (06) :1127-1132
[37]   LONG-TERM PACING IN SINUS NODE DISEASE - EFFECTS OF STIMULATION MODE ON CARDIOVASCULAR MORBIDITY AND MORTALITY [J].
ROSENQVIST, M ;
BRANDT, J ;
SCHULLER, H .
AMERICAN HEART JOURNAL, 1988, 116 (01) :16-22
[38]   ATRIAL VERSUS VENTRICULAR PACING IN SINUS NODE DISEASE - A TREATMENT COMPARISON STUDY [J].
ROSENQVIST, M ;
BRANDT, J ;
SCHULLER, H .
AMERICAN HEART JOURNAL, 1986, 111 (02) :292-297
[39]   CHRONIC ATRIAL-FIBRILLATION AND STROKE IN PACED PATIENTS WITH SICK SINUS SYNDROME - RELEVANCE OF CLINICAL CHARACTERISTICS AND PACING MODALITIES [J].
SGARBOSSA, EB ;
PINSKI, SL ;
MALONEY, JD ;
SIMMONS, TW ;
WILKOFF, BL ;
CASTLE, LW ;
TROHMAN, RG .
CIRCULATION, 1993, 88 (03) :1045-1053
[40]   AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PERMANENT PACEMAKER INTERACTION - LOSS OF PACEMAKER CAPTURE FOLLOWING AICD DISCHARGE [J].
SLEPIAN, M ;
LEVINE, JH ;
WATKINS, L ;
BRINKER, J ;
GUARNIERI, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05) :1194-1197