Au-nanocluster emission based glucose sensing

被引:93
作者
Hussain, A. M. P. [2 ]
Sarangi, S. N. [1 ]
Kesarwani, J. A. [3 ]
Sahu, S. N. [1 ]
机构
[1] Inst Phys, Bhubaneswar 751005, Orissa, India
[2] Cotton Coll, Dept Phys, Gauhati 781001, Assam, India
[3] Ayush Hosp, Bhubaneswar 751022, Orissa, India
关键词
Gold cluster; Fluorescence; Glucose biosensor; Optical absorption; C-PEPTIDE; NANOPARTICLES; FLUORESCENCE; OXIDASE; SENSOR; GOLD; SENSITIVITY; SCATTERING;
D O I
10.1016/j.bios.2011.07.066
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Fabrication of a glucose biosensor based on Au-cluster emission quenching in the UV region is reported. The glucose biosensor is highly sensitive to beta-D-glucose in 2.5-25.0 mM range as confirmed from a linear calibration plot between Au-cluster colloid emission intensity as a function of beta-D-glucose concentration. The interaction of beta-D-glucose with L-cysteine capped Au cluster colloids has been confirmed from their Fourier transformed infrared spectroscopy (FTIR) measurements. It has been found that the biomolecules present in the serum such as ascorbic and uric acids, proteins and peptides do not interfere and affect in glucose estimation as confirmed from their absorption and fluorescence (FL) emission measurements. Practical utility of this sensor based on FL quenching method has been demonstrated by estimating the glucose level in human serum that includes diabetes and the data were found to be comparable or more accurate than those of the pathological data obtained from a local hospital. In addition, this biosensor is useful to detect glucose level over a wide range with sensor response time of the order of nano to picoseconds that is emission lifetime of Au clusters. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 35 条
[1]
Biosensing with plasmonic nanosensors [J].
Anker, Jeffrey N. ;
Hall, W. Paige ;
Lyandres, Olga ;
Shah, Nilam C. ;
Zhao, Jing ;
Van Duyne, Richard P. .
NATURE MATERIALS, 2008, 7 (06) :442-453
[2]
New optical scheme for a polarimetric-based glucose sensor [J].
Ansari, RR ;
Böckle, S ;
Rovati, L .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :103-115
[3]
Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing [J].
Asher, SA ;
Alexeev, VL ;
Goponenko, AV ;
Sharma, AC ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (11) :3322-3329
[4]
Saccharide sensing using gold and silver nanoparticles - A review [J].
Aslan, K ;
Zhang, J ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2004, 14 (04) :391-400
[5]
Nanogold-plasmon-resonance-based glucose sensing [J].
Aslan, K ;
Lakowicz, JR ;
Geddes, CD .
ANALYTICAL BIOCHEMISTRY, 2004, 330 (01) :145-155
[6]
Quenched emission of fluorescence by ligand functionalized gold nanoparticles [J].
Aslan, K ;
Pérez-Luna, VH .
JOURNAL OF FLUORESCENCE, 2004, 14 (04) :401-405
[7]
A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4185-4192
[8]
Near-infrared optical sensors based on single-walled carbon nanotubes [J].
Barone, PW ;
Baik, S ;
Heller, DA ;
Strano, MS .
NATURE MATERIALS, 2005, 4 (01) :86-U16
[9]
Application of enzyme field-effect transistors for determination of glucose concentrations in blood serum [J].
Dzyadevich, SV ;
Korpan, YI ;
Arkhipova, VN ;
Alesina, MY ;
Martelet, C ;
El'Skaya, AV ;
Soldatkin, AP .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) :283-287
[10]
C-peptide and glucose values in the peritransplant period after intraportal islet infusions in type 1 diabetes [J].
Faradji, RN ;
Monroy, K ;
Cure, P ;
Froud, T ;
Baidal, D ;
Pileggi, A ;
Messinger, S ;
Ricordi, C ;
Alejandro, R .
TRANSPLANTATION PROCEEDINGS, 2005, 37 (08) :3433-3434