A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

被引:113
作者
Jarry, G [1 ]
DeMarco, JJ
Beifuss, U
Cagnon, CH
McNitt-Gray, MF
机构
[1] McGill Univ, Med Phys Unit, Montreal Gen Hosp, Montreal, PQ, Canada
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90095 USA
[3] BrainLAG AG, Munich, Germany
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
关键词
D O I
10.1088/0031-9155/48/16/306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values published by the UK's ImPACT group for a scan using an equivalent scanner, kVp, collimation, pitch and mAs. The CT source model was shown to calculate both a relative and absolute radiation dose distribution throughout the entire volume in a patient-specific matrix geometry. Results of initial testing are promising and application to patient models was shown to be feasible.
引用
收藏
页码:2645 / 2663
页数:19
相关论文
共 26 条
[1]  
[Anonymous], 1982, S885 GSF
[2]   Energy imparted and effective doses in computed tomography [J].
Atherton, JV ;
Huda, W .
MEDICAL PHYSICS, 1996, 23 (05) :735-741
[3]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[4]  
BRIESMEISTER JF, 1997, LA12625 LOS ALM NAT
[5]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225
[6]   A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :219-229
[7]   Monte Carlo calculated effective dose to teenage girls from computed tomography examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
RADIATION PROTECTION DOSIMETRY, 2000, 90 (04) :445-448
[8]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11
[9]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[10]  
Hubbell J. H., 1995, 5632 NISTIR