Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV

被引:634
作者
Boone, JM
Seibert, JA
机构
[1] Department of Radiology, University of California, Davis, Sacramento, CA 95817
[2] Department of Radiology, UC Davis Medical Center, FOLB II E, Sacramento, CA 95817
关键词
x ray; computer simulation; spectra; computer model; detective quantum efficiency;
D O I
10.1118/1.597953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to compute x-ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP is not semi-empirical and uses no physical assumptions regarding x-ray production, but rather interpolates measured constant potential x-ray spectra published by Fewell et al. [Handbook of Computed Tomography X-ray Spectra (U.S. Government Printing Office, Washington, D.C., 1981)]. X-ray output measurements (mR/mAs measured at 1 m) were made on a calibrated constant potential generator in our laboratory from 50 kV to 124 kV, and with 0-5 mm added aluminum filtration. The Fewell spectra were slightly modified (numerically hardened) and normalized based on the attenuation and output characteristics of a constant potential generator and metal-insert x-ray tube in our laboratory. Then, using the modified Fewell spectra of different kVs, the photon fluence phi at each 1 keV energy bin (E) over energies from 10 keV to 140 keV was characterized using polynomial functions of the form phi(E) = a(0)[E] + a(1)[E] kV + a(2)[E] kV(2) +...+ a(n)[E] kV(n). A total of 131 polynomial functions were used to calculate accurate x-ray spectra, each function requiring between two and four terms. The resulting TASMIP algorithm produced x-ray spectra that match both the quality and quantity characteristics of the x-ray system in our laboratory. For photon fluences above 10% of the peak fluence in the spectrum, the average percent difference (and standard deviation) between the modified Fewell spectra and the TASMIP photon fluence was -1.43% (3.8%) for the 50 kV spectrum, -0.89% (1.37%) for the 70 kV spectrum, and for the 80, 90, 100, 110, 120, 130 and 140 kV spectra, the mean differences between spectra were all less than 0.20% and the standard deviations were less than similar to 1.1%. The model was also extended to include the effects of generator-induced kV ripple. Finally, the x-ray photon fluence in the units of photons/mm(2) per mR was calculated as a function of HVL, kV, and ripple factor, for various (water-equivalent) patient thicknesses (0, 10, 20, and 30 cm). These values may be useful for computing the detective quantum efficiency, DQE(f), of x-ray detector systems. The TASMIP algorithm and ancillary data are made available on line at http://www.aip. org/epaps/epaps. html. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1661 / 1670
页数:10
相关论文
共 29 条
[1]
*AIP, EMPHYA241661 EPAPS A
[2]
DETERMINATION OF DIAGNOSTIC-X-RAY SPECTRA WITH CHARACTERISTIC RADIATION USING ATTENUATION ANALYSIS [J].
ARCHER, BR ;
WAGNER, LK .
MEDICAL PHYSICS, 1988, 15 (04) :637-641
[3]
LAPLACE RECONSTRUCTION OF EXPERIMENTAL DIAGNOSTIC-X-RAY SPECTRA [J].
ARCHER, BR ;
FEWELL, TR ;
WAGNER, LK .
MEDICAL PHYSICS, 1988, 15 (06) :832-837
[4]
Bevington R., 1969, DATA REDUCTION ERROR
[5]
COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[6]
A COMPARISON OF SEMIEMPIRICAL MODELS FOR GENERATING TUNGSTEN TARGET X-RAY-SPECTRA [J].
BISSONNETTE, JP ;
SCHREINER, LJ .
MEDICAL PHYSICS, 1992, 19 (03) :579-582
[7]
THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[8]
EQUIVALENT SPECTRA AS A MEASURE OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1986, 13 (06) :861-868
[9]
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[10]
EXPERIMENTAL AND THEORETICAL X-RAY-IMAGING PERFORMANCE COMPARISON OF IODINE AND LANTHANIDE CONTRAST AGENTS [J].
CARDINAL, HN ;
HOLDSWORTH, DW ;
DRANGOVA, M ;
HOBBS, BB ;
FENSTER, A .
MEDICAL PHYSICS, 1993, 20 (01) :15-31