Application of ion chromatography to the analysis of high-purity CdTe

被引:13
作者
Buldini, PL
Cavalli, S
Mevoli, A
Milella, E
机构
[1] CNR,AREA RIC BOLOGNA,I-40129 BOLOGNA,ITALY
[2] DIONEX SRL,LAB APPLICAZ,I-20090 PIEVE EMANUELE,ITALY
[3] PASTIS SCPA,I-72100 BRINDISI,ITALY
关键词
metal cations; inorganic anions; UV photolysis; semiconductors;
D O I
10.1016/0021-9673(96)00220-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion chromatography is widely used in different fields of analytical chemistry and there is an extensive literature dealing with it, but not many papers describe the application of ion chromatography to the analysis of high-purity materials. A matter of topical interest in this field is the determination of impurity or dopant elements in the high-purity semiconductor compounds of A(II)B(VI) type (CdTe) with detection limits from 10(-4)% to 10(-6)%. In order to eliminate the matrix effects and to reduce the detection limits, methods of concentration are commonly used; ion chromatography has been proved successful to separate impurities in the presence of large amounts of micro- and macro-components without any preconcentration and/or pre-separation steps. The proposed procedure deals with the ion chromatographic determination of chlorine, sulphur, selenium and phosphorus using a NaOH eluent, iron and copper using a PDCA eluent, lead, cobalt, zinc and nickel using an oxalate eluent. Detection limits range between 1 and 3 10(-5)% and calibration curves were found to be linear up to three orders of magnitude higher,The clear sample solutions were injected directly on to an ion chromatograph equipped both with a conductivity detector, for the determination of chloride, sulphate, selenate and phosphate ions, and a post-column membrane reactor and variable-wavelength UV-Vis detector, for the determination of iron, copper, lead, cobalt, zinc, nickel (and cadmium, if required). Ion chromatographic responses were compared to graphite furnace atomic absorption spectrometry and results were found to be in good agreement (+/-5%).
引用
收藏
页码:131 / 137
页数:7
相关论文
共 11 条
[1]   APPLICATION OF QUANTITATIVE SIMS TO DETERMINE THE INFLUENCE OF IMPURITIES ON THE ELECTRICAL-PROPERTIES OF MERCURY CADMIUM TELLURIDE [J].
BOTHA, AP ;
STRYDOM, HJ ;
MARAIS, MA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 35 (3-4) :420-422
[2]   DETERMINATION OF TOTAL PHOSPHORUS IN SOAPS/DETERGENTS BY ION CHROMATOGRAPHY [J].
BULDINI, PL ;
SHARMA, JL ;
FERRI, D .
JOURNAL OF CHROMATOGRAPHY A, 1993, 654 (01) :129-134
[3]  
BULDINI PL, 1996, IN PRESS J CHROMAT A
[4]   AN EVALUATION OF ANALYTICAL TECHNIQUES RELATED TO CADMIUM TELLURIDE PURITY AND PROCESSING [J].
DEAN, BE ;
JOHNSON, CJ ;
KRAMER, FJ .
JOURNAL OF CRYSTAL GROWTH, 1990, 106 (01) :47-50
[5]  
GRAZHULENE SS, 1984, MIKROCHIM ACTA, V1, P301
[6]  
GRAZHULENE SS, 1983, RADIOCHEM RADIOA LET, V59, P225
[7]  
GRAZHULENE SS, 1988, ZH ANAL KHIM, V43, P389
[8]  
KAPLIN AA, 1988, ZH ANAL KHIM, V43, P980
[10]  