Quantitative diffusion coefficient maps using fast spin-echo MRI

被引:28
作者
Brockstedt, S [1 ]
Thomsen, C [1 ]
Wirestam, R [1 ]
Holtås, S [1 ]
Ståhlberg, F [1 ]
机构
[1] Univ Lund Hosp, Dept Radiat Phys, Jubileum Inst, S-22185 Lund, Sweden
关键词
diffusion; fast spin-echo; motion-compensating gradients; phase correction; navigator echoes;
D O I
10.1016/S0730-725X(98)00002-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence, The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes, Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients, The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written, Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28-50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:877 / 886
页数:10
相关论文
共 40 条
  • [1] ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING
    ANDERSON, AW
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 379 - 387
  • [2] DIFFUSION-WEIGHTED MR MICROSCOPY WITH FAST SPIN-ECHO
    BEAULIEU, CF
    ZHOU, XH
    COFER, GP
    JOHNSON, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 201 - 206
  • [3] BECKER CR, 1994, MAGN RESON IMAGING, V12, P167
  • [4] BROCKSTEDT S, 1995, ACTA RADIOL, V36, P662
  • [5] BROCKSTEDT S, 1995, P 7 ANN M SOC MAGN R, V2, P905
  • [6] THE DIFFUSION SENSITIVITY OF FAST STEADY-STATE FREE PRECESSION IMAGING
    BUXTON, RB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 235 - 243
  • [7] EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS
    CARR, HY
    PURCELL, EM
    [J]. PHYSICAL REVIEW, 1954, 94 (03): : 630 - 638
  • [8] ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING
    CRAWLEY, AP
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) : 34 - 47
  • [9] IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART
    EDELMAN, RR
    GAA, JC
    WEDEEN, VJ
    LOH, E
    HARE, JM
    PRASAD, P
    LI, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 423 - 428
  • [10] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263