The implications of constraint in lumbar total disc replacement

被引:63
作者
Huang, RC
Girardi, FP
Cammisa, FP
Wright, TM
机构
[1] Hosp Special Surg, Spine Surg Serv, New York, NY 10021 USA
[2] Hosp Special Surg, Biomech & Biomat Lab, New York, NY 10021 USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2003年 / 16卷 / 04期
关键词
constraint; biomechanics; design; disc replacement; lumbar;
D O I
10.1097/00024720-200308000-00014
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Lumbar total disc replacement (TDR) is an evolving technique that has the potential to replace arthrodesis as the gold standard surgical treatment of degenerative disc disease. The interaction between host anatomy and physiology and the biomechanical properties of TDR implants will determine the quality of long-term clinical results. However, there is scant literature addressing this subject. The purpose of this article is to discuss the implications of biomechanical constraint in TDR. Based upon available data for normal motion segments and the design of two TDRs currently in clinical trials, unconstrained designs appear to have a kinematic advantage. They are more likely to provide a physiologic mobile instantaneous axis of rotation (IAR), which may explain why they display greater range of motion in vivo. Their lack of constraint may prevent excessive facet joint or capsuloligamentous loads in the extremes of flexion and extension. Furthermore, since the IAR is mobile, they may be less sensitive to small errors in implant placement. On the other hand, constrained devices appear to have an advantage in protection of the posterior elements from shear loading. Spinal shear loads of considerable magnitude occur during activities of daily living. Whether the transference of stresses to the implant and implant-bone interface is clinically significant is unknown. Although this article focuses on two specific TDR designs, future designs will need to account for the same kinematic and loading concerns regarding constraint. We hope this discussion will assist clinicians and researchers in the design, selection, and clinical comparison of present and future TDR implants.
引用
收藏
页码:412 / 417
页数:6
相关论文
共 30 条
[1]
Indications for full prosthetic disc arthroplasty: a correlation of clinical outcome against a variety of indications [J].
Bertagnoli, R ;
Kumar, S .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S131-S136
[2]
Chronic low back pain [J].
Borenstein, DG .
RHEUMATIC DISEASE CLINICS OF NORTH AMERICA, 1996, 22 (03) :439-+
[3]
SPINE UPDATE - AGING AND DEGENERATION OF THE HUMAN INTERVERTEBRAL DISC [J].
BUCKWALTER, JA .
SPINE, 1995, 20 (11) :1307-1314
[4]
Lumbar facet pain: Biomechanics, neuroanatomy and neurophysiology [J].
Cavanaugh, JM ;
Ozaktay, AC ;
Yamashita, HT ;
King, AI .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1117-1129
[5]
Results of disc prosthesis after a minimum follow-up period of 2 years [J].
Cinotti, G ;
David, T ;
Postacchini, F .
SPINE, 1996, 21 (08) :995-1000
[6]
Load-Sharing Between Anterior and Posterior Elements in a Lumbar Motion Segment Implanted With an Artificial Disc [J].
Dooris, Andrew P. ;
Goel, Vijay K. ;
Grosland, Nicole M. ;
Gilbertson, Lars G. ;
Wilder, David G. .
SPINE, 2001, 26 (06) :E122-E129
[7]
Low back pain and the zygapophysial (facet) joints [J].
Dreyer, SJ ;
Dreyfuss, PH .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (03) :290-300
[8]
ARTIFICIAL DISC REPLACEMENT - PRELIMINARY-REPORT WITH A 3-YEAR MINIMUM FOLLOW-UP [J].
ENKER, P ;
STEFFEE, A ;
MCMILLIN, C ;
KEPPLER, L ;
BISCUP, R ;
MILLER, S .
SPINE, 1993, 18 (08) :1061-1070
[9]
The effect of nucleotomy on lumbar spine mechanics in compression and shear loading [J].
Frei, H ;
Oxland, TR ;
Rathonyi, GC ;
Nolte, LP .
SPINE, 2001, 26 (19) :2080-2089
[10]
DETERMINATION OF A LOCUS OF INSTANTANEOUS CENTERS OF ROTATION OF THE LUMBAR-DISK BY MOIRE FRINGES - A NEW TECHNIQUE [J].
GERTZBEIN, SD ;
HOLTBY, R ;
TILE, M ;
KAPASOURI, A ;
CHAN, KW ;
CRUICKSHANK, B .
SPINE, 1984, 9 (04) :409-413