Accurate determination of spin-density and T1 in the presence of RF-field inhomogeneities and flip-angle miscalibration

被引:124
作者
Venkatesan, R [1 ]
Lin, WL [1 ]
Haacke, EM [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, MR Phys Lab, St Louis, MO 63110 USA
关键词
D O I
10.1002/mrm.1910400412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented for the accurate extraction of relative spin-density (rho(0)) and spin-lattice relaxation time (T-1) in the presence of RF-field inhomogeneities and flip-angle miscalibration, The method requires collecting images at several flip-angles with a three-dimensional, spoiled steady-state, gradient-echo imaging sequence, Results show that the predominant effect of an overestimated flip-angle is to shift the T-1 estimate to a higher value, whereas reductions in the normalized RF-field from unity cause rho(0) and T-1 distributions to be skewed toward lower values. Phantom and in vivo results demonstrate that the proposed method overcomes both of these systematic errors. The method was shown to be valid for up to a 50% reduction in RF sensitivity. A self-consistency argument was used to validate the absence of systematic errors in the extracted rho(0) and T-1 values over a large number of voxels, This made it possible to obtain a very precise estimate of muscle T-1 at 1.5 T, yielding a 95% confidence interval of (1077.7 +/- 3.5) ms.
引用
收藏
页码:592 / 602
页数:11
相关论文
共 29 条
[1]   MODIFIED ITERATIVE MODEL BASED ON DATA EXTRAPOLATION METHOD TO REDUCE GIBBS RINGING [J].
AMARTUR, S ;
HAACKE, EM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :307-317
[2]   MAGNETIC-RESONANCE IMAGING OF BRAIN-TUMORS - MEASUREMENT OF T1 [J].
ARAKI, T ;
INOUYE, T ;
SUZUKI, H ;
MACHIDA, T ;
IIO, M .
RADIOLOGY, 1984, 150 (01) :95-98
[3]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[4]  
BOBMAN SA, 1985, AM J NEURORADIOL, V6, P265
[5]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[6]   REPRODUCIBILITY OF RELAXATION AND SPIN-DENSITY PARAMETERS IN PHANTOMS AND THE HUMAN-BRAIN MEASURED BY MR IMAGING AT 1.5-T [J].
BREGER, RK ;
WEHRLI, FW ;
CHARLES, HC ;
MACFALL, JR ;
HAUGHTON, VM .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :649-662
[7]   TUMOR DETECTION BY NUCLEAR MAGNETIC RESONANCE [J].
DAMADIAN, R .
SCIENCE, 1971, 171 (3976) :1151-&
[8]   TISSUE CHARACTERIZATION BY MAGNETIC-RESONANCE SPECTROSCOPY AND IMAGING - RESULTS OF A CONCERTED RESEARCH-PROJECT OF THE EUROPEAN-ECONOMIC-COMMUNITY .4. IN-VIVO MEASUREMENTS OF PROTON RELAXATION-TIMES IN HUMAN BRAIN, LIVER, AND SKELETAL-MUSCLE - A MULTICENTER MRI STUDY [J].
DECERTAINES, JD ;
HENRIKSEN, O ;
SPISNI, A ;
CORTSEN, M ;
RING, PB .
MAGNETIC RESONANCE IMAGING, 1993, 11 (06) :841-850
[9]   INVIVO BRAIN WATER DETERMINATION BY T1 MEASUREMENTS - EFFECT OF TOTAL WATER-CONTENT, HYDRATION FRACTION, AND FIELD-STRENGTH [J].
FATOUROS, PP ;
MARMAROU, A ;
KRAFT, KA ;
INAO, S ;
SCHWARZ, FP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :402-413
[10]   RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING [J].
FRAM, EK ;
HERFKENS, RJ ;
JOHNSON, GA ;
GLOVER, GH ;
KARIS, JP ;
SHIMAKAWA, A ;
PERKINS, TG ;
PELC, NJ .
MAGNETIC RESONANCE IMAGING, 1987, 5 (03) :201-208