On experimental data reduction for zone model validation

被引:17
作者
He, Y
机构
[1] Ctr. Environ. Safety and Risk Eng., Victoria University of Technology, Melbourne, Vic. 8001, P.O. Box 14428, MCMC
[2] Ctr. Environ. Safety and Risk Eng., Victoria University of Technology
[3] Soc. Fire Safety and Risk Eng. Soc., Institute of Engineers
关键词
zone model; average parameter; nonequilibrium state; volume weighted and reciprocal schemes; experimental validation;
D O I
10.1177/073490419701500205
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Theoretical considerations are given to experimental data reduction for zone model validations. Three schemes to obtain averaged parameters of a thermodynamic system in nonequilibrium state are discussed in the light of model validation. Examples are given to demonstrate the difference between the zone average temperatures obtained from two averaging schemes.
引用
收藏
页码:144 / 161
页数:18
相关论文
共 15 条
[1]  
BIRK DM, 1991, INTRO MATH FIRE MODE
[2]   2-ZONE MODEL FOR A SINGLE-ROOM FIRE [J].
BRANI, DM ;
BLACK, WZ .
FIRE SAFETY JOURNAL, 1992, 19 (2-3) :189-216
[3]  
COOK NH, 1963, PHYSICAL MEASUREMENT, P2
[4]   AN EXPERIMENTAL-STUDY OF UPPER HOT LAYER STRATIFICATION IN FULL-SCALE MULTI-ROOM FIRE SCENARIOS [J].
COOPER, LY ;
HARKLEROAD, M ;
QUINTIERE, J ;
RINKINEN, W .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (04) :741-749
[5]  
Friedman R., 1992, J FIRE PROT ENG, V4, P81
[6]  
HE Y, 1996, IN PRESS FIRE SAFETY
[7]   DATA REDUCTION OF ROOM TESTS FOR ZONE MODEL VALIDATION [J].
JANSSENS, M ;
TRAN, HC .
JOURNAL OF FIRE SCIENCES, 1992, 10 (06) :528-555
[8]  
Kawagoe K, 1958, 27 MIN CONSTR
[9]   VERIFICATION OF A MODEL OF FIRE AND SMOKE TRANSPORT [J].
PEACOCK, RD ;
JONES, WW ;
BUKOWSKI, RW .
FIRE SAFETY JOURNAL, 1993, 21 (02) :89-129
[10]   DATA FOR ROOM FIRE MODEL COMPARISONS [J].
PEACOCK, RD ;
DAVIS, S ;
BABRAUSKAS, V .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1991, 96 (04) :411-462