Application of rational practice and technical advances for optimizing radiation dose for chest CT

被引:39
作者
Maher, MM
Kalra, MK
Toth, TL
Wittram, C
Saini, S
Shepard, J
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Gen Elect Med Syst, Waukesha, WI USA
关键词
CT; radiation; chest; risks;
D O I
10.1097/00005382-200401000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Though clinical benefits of CT exceed the adverse effects of radiation, the increasing use of CT has raised a compelling case for reducing radiation exposure. This controversy has been compounded by the sheer magnitude of CT examinations being performed annually, alleged overuse; and inappropriate selection of optimum scanning parameters, all of which expose the patient population to increased radiation exposure. Recommended clinical strategies for radiation dose optimization include optimization of scanning parameters and creating awareness and adopting guidelines for legitimate indications for CT scanning to avoid overuse and hence, the associated over-exposure. Whereas technological advances have increased the applications of the modality, it is also assisting in development of promising techniques to reduce associated radiation exposure, while maintaining "optimum image quality" needed to make a confident diagnosis. The present pictorial essay describes the fundamentals of CT radiation exposure and need for CT radiation dose reduction on the basis of documented scanning practices and technological advances.
引用
收藏
页码:16 / 23
页数:8
相关论文
共 39 条
[1]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[2]   Low-dose computed tomography of the thorax. Experimental and clinical investigations [J].
Diederich, S ;
Lenzen, H ;
Puskas, Z ;
Koch, AT ;
Yelbuz, TM ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGE, 1996, 36 (06) :475-482
[3]   Low-dose CT: new tool for screening lung cancer? [J].
Diederich, S ;
Wormanns, D ;
Heindel, W .
EUROPEAN RADIOLOGY, 2001, 11 (10) :1916-1924
[4]  
Diederich S, 2000, CANCER, V89, P2457, DOI 10.1002/1097-0142(20001201)89:11+<2457::AID-CNCR22>3.3.CO
[5]  
2-Z
[6]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[7]  
Fattori R, 1999, J MAGN RESON IMAGING, V10, P741, DOI 10.1002/(SICI)1522-2586(199911)10:5<741::AID-JMRI19>3.3.CO
[8]  
2-0
[9]   Dose reduction on GE CT scanners [J].
Fox, SH ;
Toth, T .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :718-723
[10]   Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT [J].
Gartenschlager, M ;
Schweden, F ;
Gast, K ;
Westermeier, T ;
Kauczor, HU ;
von Zitzewitz, H ;
Thelen, M .
EUROPEAN RADIOLOGY, 1998, 8 (04) :609-614