ICP-MS determination of strontium isotope ratio in wine in order to be used as a fingerprint of its regional origin

被引:108
作者
Almeida, CM [1 ]
Vasconcelos, MTSD [1 ]
机构
[1] Univ Porto, Fac Ciencias, Dept Quim, LAQUIPAI, P-4169007 Porto, Portugal
关键词
D O I
10.1039/b100307k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A suitable methodology for determination of the Sr isotope ratio Sr-87/Sr-86 in wines by inductively coupled plasma mass spectrometry (ICP-MS) has been developed and applied to ten samples of table and fortified wines, from five different Portuguese regions and one from a French region. After a sample pre-treatment (optimised previously) by UV irradiation and a three times dilution with de-ionised water, the solution was submitted to a two-step cation-exchange chromatographic separation for efficient elimination of Rb interference. A 2.5 M HCl solution was used as eluent at a flow rate of about 1 mi min(-1). In the first separation step (the pH of introduced sample was about 4) most of the Rb was removed with the first 120 mi of eluent. The next 40 mi were collected and introduced again to the column without pH neutralisation (pH about zero). In this second separation step, the retention volumes were lower. The Sr-containing fraction (collected between 80 and 120 mi elution volumes) was used for Sr-87/Sr-86 determination by ICP-MS. For such a purpose, the solution was evaporated to near dryness, converted into the nitrate form by addition of 1 mi of concentrated HNO3 and evaporated again to near dryness. Finally, the residue was taken up in 5 mi of de-ionised water and diluted to 15 mi using 0.5% HNO3. Instrumental and sample induced mass bias corrections were required for accurate isotope ratio (IR) determinations. Either external correction with an Sr isotopic standard solution or correction using the value of the Sr-88/Sr-86 ratio (internal correction) was used for that purpose. Both were suitable under the present experimental conditions. The precisions of the Sr IR obtained in wines using the proposed method (relative standard deviations <0.3%) were sufficient to distinguish the Sr isotopic composition in wines from different regions. Therefore, the results suggest that the Sr-87/Sr-86 ratio is a promising fingerprint of wine origin.
引用
收藏
页码:607 / 611
页数:5
相关论文
共 27 条
[1]  
Almeida CMR, 1999, ANAL CHIM ACTA, V396, P45
[2]   UV-irradiation and MW-digestion pre-treatment of Port wine suitable for the determination of lead isotope ratios by inductively coupled plasma mass spectrometry [J].
Almeida, CMR ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1815-1821
[3]   Measurement of lead isotope ratios in wine by ICP-MS and its applications to the determination of lead concentration by isotope dilution [J].
Augagneur, S ;
Medina, B ;
Grousset, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1149-1152
[4]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[5]  
Baxter MJ, 1997, FOOD CHEM, V60, P443, DOI 10.1016/S0308-8146(96)00365-2
[6]   Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios [J].
Begley, IS ;
Sharp, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :395-402
[7]   ISOTOPE RATIO MASS-SPECTROMETRY - ANALYSIS OF WINES FROM DIFFERENT EUROPEAN COUNTRIES [J].
BREAS, O ;
RENIERO, F ;
SERRINI, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (12) :967-970
[8]  
Bullen TD, 1998, ISOTOPE TRACERS IN CATCHMENT HYDROLOGY, P611
[9]   87Sr/86Sr measurements on marine sediments by inductively coupled plasma-mass spectrometry [J].
Chassery, S ;
Grousset, FE ;
Lavaux, G ;
Quetel, CR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (02) :230-234
[10]  
DAY MP, 1994, AM J ENOL VITICULT, V45, P79