Effect of humidity on the sensing property of thermoelectric hydrogen sensor

被引:18
作者
Sawaguchi, N [1 ]
Shin, W [1 ]
Izu, N [1 ]
Matsubara, I [1 ]
Murayama, N [1 ]
机构
[1] AIST, Adv Mfg RI, Nagoya, Aichi 4628560, Japan
关键词
thermoelectric hydrogen sensor; humidity; FT-IR; oxidation of hydrogen; gas flow chamber; gas diffusion chamber;
D O I
10.1016/j.snb.2004.12.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas responses of thermoelectric hydrogen sensors in dry and humid atmospheres were measured to investigate the effect of humidity. The gas responses of the thermoelectric hydrogen sensor were not affected by the humidity in condition of 55 and 75% RH when the devise-operating temperature was 60-100 degrees C, however, the gas response decreased when the devise-operating temperature was at room temperature. A gas flow chamber and a gas diffusion chamber were used to measure the gas responses and the similar results were obtained from both methods. In situ FT-IR measurements were carried out to examine the state of the hydrogen oxidation on the catalyst surface by the detection of generated water molecules. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 11 条
[1]   A new highly selective H2 sensor based on TiO2/PtO-Pt dual-layer films [J].
Du, XY ;
Wang, Y ;
Mu, YY ;
Gui, LL ;
Wang, P ;
Tang, YQ .
CHEMISTRY OF MATERIALS, 2002, 14 (09) :3953-3957
[2]   Improvement of humidity dependence in gas sensor based on SnO2 [J].
Fukui, K ;
Katsuki, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) :316-318
[3]   Nano-structured thin-film Pt catalyst for thermoelectric hydrogen gas sensor [J].
Matsumiya, M ;
Shin, W ;
Izu, N ;
Murayama, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :309-315
[4]   Effects of surface modification with platinum and ruthenium on temperature and humidity dependence of SnO2-based CO gas sensors [J].
Morimitsu, M ;
Ozaki, Y ;
Suzuki, S ;
Matsunaga, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :184-188
[5]   A study of water influence on CO response on gold-doped iron oxide sensors [J].
Neri, G ;
Bonavita, A ;
Rizzo, G ;
Galvagno, S ;
Donato, N ;
Caputi, LS .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) :90-96
[6]   COMPARISON OF THE WATER EFFECT ON THE RESISTANCE OF DIFFERENT SEMICONDUCTING METAL-OXIDES [J].
RETI, F ;
FLEISCHER, M ;
GERBLINGER, J ;
LAMPE, U ;
VARHEGYI, EB ;
PERCZEL, IV ;
MEIXNER, H ;
GIBER, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) :103-107
[7]   Planar catalytic combustor film for thermoelectric hydrogen sensor [J].
Shin, W ;
Tajima, K ;
Choi, YS ;
Izu, N ;
Matsubara, I ;
Murayama, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :455-460
[8]   Hydrogen-selective thermoelectric gas sensor [J].
Shin, W ;
Matsumiya, M ;
Izu, N ;
Murayama, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :304-308
[9]   Thermoelectric thick-film hydrogen gas sensor operating at room temperature [J].
Shin, W ;
Imai, K ;
Izu, N ;
Murayama, N .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (11B) :L1232-L1234
[10]  
Sonntag D., 1990, Zeitschrift fur Meteorologie, V40, P340