Modes of failure of osteonics constrained tripolar implants: A retrospective analysis of forty-three failed implants

被引:65
作者
Guyen, Olivier [1 ]
Lewallen, David G. [1 ]
Cabanela, Miguel E. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
D O I
10.2106/JBJS.G.00317
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Methods: Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. Results: The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type 1), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type 11), in six hips; failure of the retaining mechanism of the bipolar component (type 111), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. Conclusions: The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1553 / 1560
页数:8
相关论文
共 19 条
[1]
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[2]
The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Adams, JB ;
Russell, JH ;
Groseth, KL .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :93-102
[3]
Berry D J, 2001, Instr Course Lect, V50, P265
[4]
Use of constrained acetabular components for hip instability: An average 10-year follow-up study [J].
Bremner, BRB ;
Goetz, DD ;
Callaghan, JJ ;
Capello, WN ;
Johnston, RC .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :131-137
[5]
A constrained liner cemented into a secure cementless acetabular shell [J].
Callaghan, JJ ;
Parvizi, J ;
Novak, CC ;
Bremner, B ;
Shrader, W ;
Lewallen, DG ;
Johnston, RC ;
Goetz, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2206-2211
[6]
Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty [J].
Callaghan, JJ ;
O'Rourke, MR ;
Goetz, DA ;
Lewallen, DG ;
Johnston, RC ;
Capello, WN .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :117-123
[7]
Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty [J].
Cooke, CC ;
Hozack, W ;
Lavernia, C ;
Sharkey, P ;
Shastri, S ;
Rothman, RH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :827-833
[8]
Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component [J].
Goetz, DD ;
Bremner, BRB ;
Callaghan, JJ ;
Capello, WN ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (11) :2419-2423
[9]
Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component - A retrospective analysis of fifty-six cases [J].
Goetz, DD ;
Capello, WN ;
Callaghan, JJ ;
Brown, TD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :502-509
[10]
Goetz DD, 1998, CLIN ORTHOP RELAT R, P171