A novel preconcentration method for determination of iron and lead using Chromosorb-103 and flame atomic absorption spectrometry

被引:34
作者
Bakircioglu, Y [1 ]
Bakircioglu, D
Tokman, N
机构
[1] Trakya Univ, Fac Arts & Sci, Dept Chem, TR-22030 Edirne, Turkey
[2] Istanbul Tech Univ, Fac Arts & Sci, Dept Chem, TR-80626 Istanbul, Turkey
关键词
syringe-connected minicolumn method; flame atomic absorption spectrometry; solid phase extraction; Chromosorb-103; bovine liver;
D O I
10.1016/j.aca.2005.01.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Syringe connected-minicolumn (SCM) method for the preconcentration/separation of iron and lead prior to their determination by flame atomic absorption spectrometry (FAAS) was developed. The proposed method is substituted for classical batch and column methods. The method proposed was compared with the column method with respect to easiness, rapidness, simplicity and some analytical performance criteria such as recovery, precision, accuracy and risk of contamination. A minicolumn was filled with Chromosorb-103 as a sorbent and connected with a syringe. The experimental conditions such as pH of sample, concentration and amount of eluent, flow rates of sample and eluent, concentration of 8-hydroxyquinoline (oxine) as a complexing agent were optimized. The sample solution with or without oxine was drawn into the syringe and discharged manually passing through the resin. Analytes were retained at pH >= 5 and eluted with I M nitric acid in acetone quantitatively. Analyte elements could be concentrated up to 200-fold. The iron and lead in river-water samples and in certified reference Bovine Liver (NIST 1577b) were quantitatively recovered with relative standard deviation lower than 10%. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 23 条
[1]   Determination of cadmium and lead in biological samples by Zeeman ETAAS using various chemical modifiers [J].
Acar, O .
TALANTA, 2001, 55 (03) :613-622
[2]   Determination of lead and nickel in Apple-Leaves and seawater by electrothermal atomic absorption spectrometry after solid-phase extraction using Chromosorb-107 filled in a syringe [J].
Akman, S ;
Tokman, N .
TALANTA, 2003, 60 (01) :199-204
[3]   Use of a syringe-mountable filter resin technique for the separation and enrichment of lead and cadmium prior to their determination by flame atomic absorption spectrometry [J].
Akman, S ;
Ozcan, M ;
Demirel, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :743-745
[4]   Solid phase extraction of bismuth and chromium by rice husk [J].
Bakircioglu, Y ;
Bakircioglu, D ;
Akman, S .
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2003, 21 (03) :467-478
[5]   Evaluation of Pb-Spec® for flow-injection solid-phase extraction preconcentration for the determination of trace lead in water and wine by flame atomic absorption spectrometry [J].
Bakircioglu, Y ;
Segade, SR ;
Yourd, ER ;
Tyson, JF .
ANALYTICA CHIMICA ACTA, 2003, 485 (01) :9-18
[6]   Preconcentration of cobalt with 8-hydroxyquinoline and gas chromatographic stationary phase Chromosorb 105 and its determination by graphite furnace atomic absorption spectrometry [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF .
TALANTA, 2002, 57 (06) :1173-1180
[7]   Evaluation of several gas chromatographic stationary phases for the solid-phase extraction of trace amounts of copper in aqueous samples [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
He, B .
ANALYTICAL SCIENCES, 2002, 18 (06) :705-707
[8]   Preconcentration of trace amounts of cadmium in aqueous samples on minicolumns packed with Chromosorb series gas chromatographic stationary phases and its determination by electrothermal atomic absorption spectrometry [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF .
ANALYST, 2001, 126 (10) :1678-1682
[9]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[10]   Multivariate optimization of solvent extraction of Cd(II), Co(II), Cr(VI), Cu(II), Ni(II), Pb(II) and Zn(II) as dibenzyldithiocarbamates and detection by AAS [J].
Camino, M ;
Bagur, MG ;
Sánchez-Viñas, M ;
Gázquez, D ;
Romero, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :638-642