Determination of cadmium and lead in biological samples by Zeeman ETAAS using various chemical modifiers

被引:51
作者
Acar, O [1 ]
机构
[1] TAEK, Ankara Nukl Arastirma Egitim Merkezi, TR-06100 Ankara, Turkey
关键词
cadmium; lead; chemical modifiers; Zeeman background correction;
D O I
10.1016/S0039-9140(01)00468-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrothermal atomic absorption spectrometric determination of cadmium and lead in biological certified reference materials (CRMs) has been carried out by using NH4H2PO4, Ni, Pd, Ni + NH4H2PO4, Pd + NH4H2PO4 and Ni + Pd + NH4H2PO4 as chemical modifiers. A comprehensive comparison was made among the modifiers in 1% Triton X-100 plus 0.2% nitric acid as diluent and without modifier. Zeeman background correction and graphite tubes inserted with platforms were used. Comparison was made in terms of pyrolysis and atomization temperatures, atomization and background absorption profiles. Ni + Pd + NH4H2PO4 modifier mixture was found to be preferable for the determination of Cd and Pb. Pyrolysis temperatures of analytes were increased up to 900 degreesC for Cd and 1250 degreesC for Pb by using Ni + Pd + NH4H2PO4 in 1% Triton X-100 plus 0.2% nitric acid diluent solution. Biological CRMs were analyzed to verify the accuracy and precision of this method. Depending on the biological sample type, the percent recoveries were increased from 62 to 102% for Cd and from 58 to 106% for Pb by using the proposed modifier mixture. The detection limits of Cd and Pb were found to be 0.04, 0.92 mug l(-1), respectively. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:613 / 622
页数:10
相关论文
共 30 条
[1]   Determination of lead in cookies by electrothermal atomic absorption spectrometry with various chemical modifiers [J].
Acar, O ;
Kiliç, Z ;
Türker, AR .
FOOD CHEMISTRY, 2000, 71 (01) :117-122
[2]   Determination of bismuth, indium and lead in geological and sea-water samples by electrothermal atomic absorption spectrometry with nickel-containing chemical modifiers [J].
Acar, O ;
Kiliç, Z ;
Türker, AR .
ANALYTICA CHIMICA ACTA, 1999, 382 (03) :329-338
[3]   Direct determination of bismuth, indium and lead in sea water by Zeeman ETAAS using molybdenum containing chemical modifiers [J].
Acar, O ;
Türker, AR ;
Kiliç, Z .
TALANTA, 1999, 49 (01) :135-142
[4]  
BATH RV, 1997, WHO GENEVA TECHNICAL, V50, P132
[5]   DETERMINATION OF LEAD IN BIOLOGICAL-MATERIALS BY MICROWAVE-ASSISTED MINERALIZATION AND FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :235-241
[6]  
Burguera JL, 1997, ATOM SPECTROSC, V18, P109
[7]   LEAD AND CADMIUM CONTAMINATION IN DAIRY-PRODUCTS AND ITS REPERCUSSION ON TOTAL DIETARY-INTAKE [J].
CABRERA, C ;
LORENZO, ML ;
LOPEZ, MC .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (06) :1605-1609
[8]  
Carlosena A, 1996, FRESEN J ANAL CHEM, V355, P289
[9]   Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry [J].
Chang, CC ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (01) :75-80
[10]   Simultaneous determination of Cd and Pb in foodstuffs by electrothermal atomic absorption spectrometry [J].
Correia, PRM ;
Oliveira, E ;
Oliveira, PV .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :205-211