Continuous neonatal blood gas monitoring using a multiparameter intra-arterial sensor

被引:28
作者
Morgan, C
Newell, SJ [1 ]
Ducker, DA
Hodgkinson, J
White, DK
Morley, CJ
Church, JM
机构
[1] St James Univ Hosp, Neonatal Intens Care Unit, Leeds LS9 7TF, W Yorkshire, England
[2] All St Hosp, Chatham, Kent, England
[3] Addenbrookes Hosp, Rosie Matern Unit, Cambridge, England
[4] Diametr Med Ltd, High Wycombe, Bucks, England
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 1999年 / 80卷 / 02期
关键词
blood gas monitoring; multiparameter intra-arterial sensor;
D O I
10.1136/fn.80.2.F93
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aims-To compare arterial blood gas (ABG) readings obtained with a multiparameter intra-arterial sensor with those from an ABG analyser. Methods-An MPIAS with the ability to measure continuously pH, PaCO2, and PaO2 was introduced via an umbilical arterial catheter in 27 neonates requiring intensive care. They underwent 3260 hours of MPIAS monitoring, during which 753 ABG readings were performed. Results-Overall bias (mean difference: MPIAS-ABG) and precision (standard deviation of differences) values were: -0.002 and 0.022, respectively, for pH; +0.26 and 0.52 for PaCO2 (kPa); and -0.19 and 0.99 for PaO2 (kPa). This gave 95% limits of agreement as: -0.047 to +0.042 for pH, -0.76 to +1.28 kPa for PaCO2, and -2.13 to +1.75 kPa for PaO2. For each variable, precision across readings from the same individual was better than overall precision for all data. No complications related to the use of the catheter were observed. Conclusions-Continuous MPIAS ABG monitoring is an exciting development, with the potential to reduce blood transfusions and improve ABG homeostasis.
引用
收藏
页码:F93 / F98
页数:6
相关论文
共 30 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   SKIN SURFACE PCO2 MONITORING IN NEWBORN-INFANTS IN SHOCK - EFFECT OF HYPOTENSION AND ELECTRODE TEMPERATURE [J].
BRUNSTLER, I ;
ENDERS, A ;
VERSMOLD, HT .
JOURNAL OF PEDIATRICS, 1982, 100 (03) :454-457
[3]   A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates [J].
Carter, B ;
Hochmann, M ;
Osborne, A ;
Nisbet, A ;
Campbell, N .
ANAESTHESIA AND INTENSIVE CARE, 1995, 23 (06) :708-714
[4]   TRANS-CUTANEOUS MONITORING IN THE NEWBORN-INFANT [J].
CASSADY, G .
JOURNAL OF PEDIATRICS, 1983, 103 (06) :837-848
[5]   THE EFFECT OF FREQUENCY ON CARBON-DIOXIDE LEVELS DURING HIGH-FREQUENCY OSCILLATION [J].
CHAN, V ;
GREENOUGH, A .
JOURNAL OF PERINATAL MEDICINE, 1994, 22 (02) :103-106
[6]   FACTORS ASSOCIATED WITH PERIVENTRICULAR HEMORRHAGE IN VERY LOW-BIRTH-WEIGHT INFANTS [J].
COOKE, RWI .
ARCHIVES OF DISEASE IN CHILDHOOD, 1981, 56 (06) :425-431
[7]   MONITORING OXYGEN IN THE NEWBORN - SATURATION OR PARTIAL-PRESSURE [J].
DEAR, PRF .
ARCHIVES OF DISEASE IN CHILDHOOD, 1987, 62 (09) :879-881
[8]   USE OF A CONTINUOUSLY RECORDING INTRAVASCULAR OXYGEN ELECTRODE IN NEWBORN [J].
GODDARD, P ;
KEITH, I ;
MARCOVITCH, H ;
ROBERTON, NR ;
ROLFE, P ;
SCOPES, JW .
ARCHIVES OF DISEASE IN CHILDHOOD, 1974, 49 (11) :853-860
[9]   SEVERE HYPOCARBIA IN PRETERM INFANTS AND NEURODEVELOPMENTAL DEFICIT [J].
GREISEN, G ;
MUNCK, H ;
LOU, H .
ACTA PAEDIATRICA SCANDINAVICA, 1987, 76 (03) :401-404
[10]  
HANSEN TN, 1979, PEDIATRICS, V64, P942