Correspondence of closest gradient voxels - A robust registration algorithm

被引:56
作者
Ostuni, JL
Levin, RL
Frank, JA
DeCarli, C
机构
[1] Lab. of Diagn. Radiology Research, Natl. Inst. Neurologic Disord. S., National Institutes of Health, Bethesda, MD 20892-1074
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 02期
关键词
registration; sequence independent; robust; automatic; gradient matching; closest gradients;
D O I
10.1002/jmri.1880070227
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A robust, automatic volume registration algorithm based on intensity gradients is presented, This algorithm can successfully perform registrations under conditions of unrelated intervolume voxel intensities, significant object displacements, and/or significant amounts of missing data, It also allows the user to visualize the registration convergence, clearly illustrating any source of registration errors. This algorithm consists of a matching algorithm based on iteratively finding the correspondence of the closest voxels containing a high three-dimensional intensity gradient magnitude, This algorithm was tested by registering T2-weighted MR volumes that had undergone varying displacement transformations to simultaneously acquired proton-density volumes, These transformations involved rotations of up to 25 degrees followed by translations of up to 25 mm along the axis of rotation, For all registrations, the mean registration error was less than one-fifth of a voxel and the mean registration time was less than 30 minutes, In conclusion, this algorithm is shown to be a powerful method of sequence-independent MR volume registration that is simple to both use and understand.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 11 条
[1]  
ALBERT NM, 1990, J NUCL MED, V31, P1717
[2]  
BESI PJ, 1992, IEEE T PATTERN ANAL, V14, P239
[3]   LANDMARK BASED CORRELATION OF MEDICAL IMAGES [J].
BOESECKE, R ;
BRUCKNER, T ;
ENDE, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :121-126
[4]   EXPERIMENTAL ALLERGIC ENCEPHALOMYELITIS AND MULTIPLE-SCLEROSIS - LESION CHARACTERIZATION WITH MAGNETIZATION TRANSFER IMAGING [J].
DOUSSET, V ;
GROSSMAN, RI ;
RAMER, KN ;
SCHNALL, MD ;
YOUNG, LH ;
GONZALEZSCARANO, F ;
LAVI, E ;
COHEN, JA .
RADIOLOGY, 1992, 182 (02) :483-491
[5]  
Haralick R. M., 1992, COMPUTER ROBOT VISIO, V1
[6]   AUTOMATED REGISTRATION OF DISSIMILAR IMAGES - APPLICATION TO MEDICAL IMAGERY [J].
HERBIN, M ;
VENOT, A ;
DEVAUX, JY ;
WALTER, E ;
LEBRUCHEC, JF ;
DUBERTRET, L ;
ROUCAYROL, JC .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 47 (01) :77-88
[7]   CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING ORTHONORMAL MATRICES [J].
HORN, BKP ;
HILDEN, HM ;
NEGAHDARIPOUR, S .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (07) :1127-1135
[8]   Whole-brain functional mapping with isotropic MR imaging [J].
Mattay, VS ;
Frank, JA ;
Santha, AKS ;
Pekar, JJ ;
Duyn, JH ;
McLaughlin, AC ;
Weinberger, DR .
RADIOLOGY, 1996, 201 (02) :399-404
[9]   ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN [J].
PELIZZARI, CA ;
CHEN, GTY ;
SPELBRING, DR ;
WEICHSELBAUM, RR ;
CHEN, CT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :20-26
[10]   MRI-PET REGISTRATION WITH AUTOMATED ALGORITHM [J].
WOODS, RP ;
MAZZIOTTA, JC ;
CHERRY, SR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) :536-546