Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.OT

被引:52
作者
Bi, XM
Deshpande, V
Simonetti, O
Laub, G
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Siemens Med Solut, Chicago, IL USA
关键词
magnetic resonance angiography (MRA); coronary arteries; high-field imaging; 3T MRI; three-dimensional;
D O I
10.1002/jmri.20374
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of three-dimensional breathhold coronary magnetic resonance angiography (MRA) at 3.0T using the steady-state free precession (SSFP) sequence, and quantify the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) gains of coronary MRA from 1.5T to 3.0T using whole-body and phased-array cardiac coils as the signal receiver. Materials and Methods: Eight healthy volunteers were scanned on 1.5T and 3.0T whole-body systems using the SSFP sequence. Numerical simulations were performed for the SSFP sequence to optimize the flip angle and predict signal enhancement from 1.5T to 3.0T. Coronary artery images, were acquired with the whole-body coil in transmit-receive mode or transmit-only with phased-array cardiac coil receivers. Results: In vivo studies of the same volunteer group at both field strengths showed increases of 87% in SNR and 83% in CNR from 1.5T to 3.0T using a whole-body coil as the signal receiver. The corresponding increases using phased-array receivers were 53% in SNR and 92% in CNR. However, image quality at 3.0T was more variable than 1.5T, with increased susceptibility artifacts and local brightening as the result of increased B-0 and 131 inhomogeneities. Conclusion: Coronary MRA at 3.0T using a three-dimensional breathhold SSFP sequence is feasible. Improved SNR at 3.0T warrants the use of coronary MRA with faster acquisition and/or improved spatial resolution. Further investigations are required to improve the consistency of image quality and signal uniformity at 3.0T.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 26 条
[1]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[2]  
BENDALL MR, 1987, MAGNET RESON MED, V4, P493
[3]   Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography [J].
Bi, XM ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :133-139
[4]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[5]   Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency [J].
Deshpande, VS ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :803-809
[6]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[7]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[8]   MUSCULOSKELETAL MR-IMAGING AT 4 T AND AT 1.5 T - COMPARISON OF RELAXATION-TIMES AND IMAGE-CONTRAST [J].
DUEWELL, SH ;
CECKLER, TL ;
ONG, K ;
WEN, H ;
JAFFER, FA ;
CHESNICK, SA ;
BALABAN, RS .
RADIOLOGY, 1995, 196 (02) :551-555
[9]   TrueFISP - technical considerations and cardiovascular applications [J].
Fuchs, F ;
Laub, G ;
Othomo, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (01) :28-32
[10]   Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T [J].
Greenman, RL ;
Shirosky, JE ;
Mulkern, RV ;
Rofsky, NM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) :648-655