TrueFISP - technical considerations and cardiovascular applications

被引:77
作者
Fuchs, F
Laub, G
Othomo, K
机构
[1] Magnet Resonance Div, D-91052 Erlangen, Germany
[2] MR Res & Dev, Siemens Med Solut, Chicago, IL 60611 USA
[3] Univ Tokyo, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
magnetic resonance; heart; SSFP imaging;
D O I
10.1016/S0720-048X(02)00330-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) using steady-state free precession (SSFP) sequences was described in the early years of MR imaging. However, due to hardware imperfections, these techniques were not robust enough at the time to play any significant role in clinical MRI. More recently, significant hardware improvements became widely available, and the SSFP sequences such as TrueFISP (true fast imaging with steady-state precession) became very popular for a variety of clinical applications due to the distinct improvements in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The purpose of this article is to give an overview on the basics of TrueFISP imaging and to demonstrate its potential for current clinical applications with a focus on cardiovascular MRI. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 39 条
[1]   Comparison of right ventricular volume measurement between segmented K-space gradient-echo and steady-state free precession magnetic resonance Imaging [J].
Alfakih, K ;
Thiele, H ;
Plein, S ;
Bainbridge, GJ ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (03) :253-258
[2]   Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries [J].
Barkhausen, J ;
Hunold, P ;
Jochims, M ;
Eggebrecht, H ;
Sabin, GV ;
Erbel, R ;
Debatin, JF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06) :725-730
[3]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[4]   Steady-state preparation for spoiled gradient echo imaging [J].
Busse, RF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :653-661
[5]  
Carr J C, 2001, Top Magn Reson Imaging, V12, P349, DOI 10.1097/00002142-200110000-00005
[6]   High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation [J].
Carr, JC ;
Ma, J ;
Desphande, V ;
Pereles, S ;
Laub, G ;
Finn, JP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :543-549
[7]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[8]   Transmural extent of acute myocardial infarction predicts long-term improvement in contractile function [J].
Choi, KA ;
Kim, RJ ;
Gubernikoff, G ;
Vargas, JD ;
Parker, M ;
Judd, RA .
CIRCULATION, 2001, 104 (10) :1101-1107
[9]  
CHUNG Y, 2001, SCMR 2001
[10]   MR-based assessment of vascular morphology and function [J].
Debatin, JF ;
Hany, TF .
EUROPEAN RADIOLOGY, 1998, 8 (04) :528-539