Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries

被引:24
作者
Barkhausen, J
Hunold, P
Jochims, M
Eggebrecht, H
Sabin, GV
Erbel, R
Debatin, JF
机构
[1] Univ Essen Gesamthsch Klinikum, Inst Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Elisabethkrankenhaus Essen, Abt Kardiol, Essen, Germany
[3] Univ Essen Gesamthsch Klinikum, Zentrum Innere Med, Abt Kardiol, D-45122 Essen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 06期
关键词
magnetic resonance imaging; magnetic resonance angiography; coronary arteries; fast imaging;
D O I
10.1055/s-2002-32226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Purpose of our study was to compare the image quality of 3D-navigator steady state free precession (SSFP) and gradient echo (GE) sequences for magnetic resonance coronary angiography (MRCA) in volunteers and patients. Methods: Following informed consent 8 volunteers and 12 patients were included into this study. In all subjects a 3D navigator MRCA of the right and the left coronary artery was performed with a SSFP (TR 3.9 ms, TE 1.7 ms, FA 65degrees, bandwidth 540 Hz) and a GE (TR 5.8 ms, TE 2.2 ms, FA 25degrees, bandwidth 200 Hz) sequence using a 1.5T-MR-System (Magnetom Sonata, Siemens Erlangen). The slice thickness was 1.5 mm and the in-plane resolution was 0.9 x 0.7 mm(2) for all measurements. Results: The blood pool showed a significantly (p < 0.01) higher signal intensity on SSFP images (147 +/- 36) compared to GE images (103 36). Although noise increased with SSFP (9.3 +/- 1.4 versus 5.3 +/- 0.9), the contrast-to-noise ratio between myocardium and the coronaries was significantly (p < 0.01) higher on SSFP images (7.8 +/- 3.7 versus 3.4 +/- 3.3). The CNR between the coronaries and the epicardial fat showed no significant differences (12 +/- 5 versus 13 +/- 4). Conclusion: The 3D-navigator SSFP sequence is a promising new technique for MRCA which improves the contrast between the coronaries and the myocardium and shortens the data acquisition compared to gradient-echo imaging.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 27 条
[1]   Noninvasive coronary angiography - An acceptable alternative? [J].
Achenbach, S ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1909-1910
[2]  
Achenbach S, 2001, AM J CARDIOL, V88, p70E
[3]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[4]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[5]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[6]  
BRUCKENBERGER E, 2001, HERZBERCHT 2000 TRAN
[7]   Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[8]  
DAVIDSON CJ, 1992, HEART DIS, P177
[9]   MR-based assessment of vascular morphology and function [J].
Debatin, JF ;
Hany, TF .
EUROPEAN RADIOLOGY, 1998, 8 (04) :528-539
[10]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502