摘要
Magnetic resonance imaging (MRI) using steady-state free precession (SSFP) sequences was described in the early years of MR imaging. However, due to hardware imperfections, these techniques were not robust enough at the time to play any significant role in clinical MRI. More recently, significant hardware improvements became widely available, and the SSFP sequences such as TrueFISP (true fast imaging with steady-state precession) became very popular for a variety of clinical applications due to the distinct improvements in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The purpose of this article is to give an overview on the basics of TrueFISP imaging and to demonstrate its potential for current clinical applications with a focus on cardiovascular MRI. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 39 条
[21]   Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion [J].
Lee, VS ;
Resnick, D ;
Bundy, JM ;
Simonetti, OP ;
Lee, P ;
Weinreb, JC .
RADIOLOGY, 2002, 222 (03) :835-842
[22]   Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI - Comparison with dobutamine stress echocardiography [J].
Nagel, E ;
Lehmkuhl, HB ;
Bocksch, W ;
Klein, C ;
Vogel, U ;
Frantz, E ;
Ellmer, A ;
Dreysse, S ;
Fleck, E .
CIRCULATION, 1999, 99 (06) :763-770
[23]  
Nayak KS, 2001, MAGNET RESON MED, V45, P371, DOI 10.1002/1522-2594(200103)45:3<371::AID-MRM1048>3.0.CO
[24]  
2-Z
[25]  
OPPELT A, 1986, Electromedica (English Edition), V54, P15
[26]   Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study [J].
Oudkerk, M ;
van Beek, EJR ;
Wielopolski, P ;
van Ooijen, PMA ;
Brouwers-Kuyper, EMJ ;
Bongaerts, AHH ;
Berghout, A .
LANCET, 2002, 359 (9318) :1643-1647
[27]   Abnormal subendocardial perfusion in cardiac syndrome X detected by cardiovascular magnetic resonance imaging [J].
Panting, JR ;
Gatehouse, PD ;
Yang, GZ ;
Grothues, F ;
Firmin, DN ;
Collins, P ;
Pennell, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (25) :1948-1953
[28]  
Panting JR, 2001, J MAGN RESON IMAGING, V13, P192
[29]   Cardiovascular magnetic resonance [J].
Pennell, D .
HEART, 2001, 85 (05) :581-589
[30]   Thoracic aortic dissection and aneurysm: Evaluation with nonenhanced true FISP MR angiography in less than 4 minutes [J].
Pereles, FS ;
McCarthy, RM ;
Baskaran, V ;
Carr, JC ;
Kapoor, V ;
Krupinski, EA ;
Finn, JP .
RADIOLOGY, 2002, 223 (01) :270-274