Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion

被引:90
作者
Lee, VS
Resnick, D
Bundy, JM
Simonetti, OP
Lee, P
Weinreb, JC
机构
[1] NYU, Med Ctr, Dept Radiol MRI, New York, NY 10016 USA
[2] Siemens Med Syst Inc, Chicago, IL USA
关键词
heart; MR; ventricles; volume; magnetic resonance (MR); cine study; pulse sequences; volume measurement;
D O I
10.1148/radiol.2223011156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section position, nine short-axis section positions per breath hold). Contrast-to-noise ratios (CNRs) and left ventricular mass and function measurements with this technique were compared in all subjects with single-section true FISP imaging and, in the volunteers only, with segmented fast low-angle shot (FLASH) MR imaging. Myocardium-to-blood CNR was significantly higher for both true FISP sequences compared with the FLASH sequence. Measurements of resting left ventricular function with real-time true FISP imaging were comparable with those derived from a series of separate breath-hold single-section true FISP acquisitions. (C) RSNA, 2002.
引用
收藏
页码:835 / 842
页数:8
相关论文
共 35 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Multi-slice dynamic imaging: Complete functional cardiac MR examination within 15 seconds [J].
Bornstedt, A ;
Nagel, E ;
Schalla, S ;
Schnackenburg, B ;
Klein, C ;
Fleck, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :300-305
[5]  
BUNDY JM, 1999, P 7 M INT SOC MAGN R, V7, P1282
[6]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[7]  
Chung YC, 1999, MAGNET RESON MED, V42, P335, DOI 10.1002/(SICI)1522-2594(199908)42:2<335::AID-MRM16>3.0.CO
[8]  
2-K
[9]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[10]  
Fang W, 2000, P INT SOC MAGN RESON, V8, P308