Comparison of right ventricular volume measurement between segmented K-space gradient-echo and steady-state free precession magnetic resonance Imaging

被引:48
作者
Alfakih, K [1 ]
Thiele, H [1 ]
Plein, S [1 ]
Bainbridge, GJ [1 ]
Ridgway, JP [1 ]
Sivananthan, MU [1 ]
机构
[1] Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
关键词
magnetic resonance imaging; heart; steady-state imaging; gradient-echo imaging right ventricular volumes; observer variability;
D O I
10.1002/jmri.10164
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare right ventricular volume measurements and their reproductibility between steady-state free precession (SSFR) and conventional turbo gradient-echo (TGE) imaging. Materials and Methods: Right ventricular volumes and observer variabilities were compared between SSFP and TGE in 31 subjects (21 normal volunteers and 10 subjects with heart failure). For further internal validation of the right ventricular volumes, the left ventricle (LV) and right ventricle (RV) stroke volumes were compared for the normal volunteers. Results: The volumes as measured by SSFP were significantly larger than for TGE (mean bias end-diastolic volume [EDV] 11.1 +/- 14.2, end-systolic volume [ESV] 9.8 +/- 9.75]. SSFP had lowere interobserver variability [SSFP EDV -10.1 +/- 11.6 vs. TGE EDV -6.2 +/- 18.5) and intra-observer variability (SSFP EDV -2.0 +/- 6.3vs. TGE EDV -6.1 +/- 14.8). The mean absolute differences between LV and RV stroke volumes for 21 normal volunteers were: TGE 5.8 +/- 12.9 (r(2) = 0.72), SSFP 4.6 +/- 6.9 (r(2) = 0.92). Conclusion: SSFP and TGE yield different measurement values of RV volumes with SSFP, providing a more reproducible measurement.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 22 条
  • [1] MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    Barkhausen, J
    Ruehm, SG
    Goyen, M
    Buck, T
    Laub, G
    Debatin, JF
    [J]. RADIOLOGY, 2001, 219 (01) : 264 - 269
  • [2] Spin echo MRI in the evaluation of hearts with a double outlet right ventricle: usefulness and limitations
    Beekman, RP
    Roest, AAW
    Helbing, WA
    Hazekamp, MG
    Schoof, PH
    Bartelings, MM
    Sobotka, MA
    de Roos, A
    Ottenkamp, J
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (03) : 245 - 253
  • [3] INFERIOR MYOCARDIAL-INFARCTION - HIGH-RISK SUBGROUPS
    BERGER, PB
    RYAN, TJ
    [J]. CIRCULATION, 1990, 81 (02) : 401 - 411
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    Carr, JC
    Simonetti, O
    Bundy, J
    Li, DB
    Pereles, S
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (03) : 828 - 834
  • [6] Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
  • [7] 2-5
  • [8] Chin BB, 1997, J NUCL MED, V38, P942
  • [9] Late pulmonary valve replacement after repair of tetralogy of Fallot
    Discigil, B
    Dearani, JA
    Puga, FJ
    Schaff, HV
    Hagler, DJ
    Warnes, CA
    Danielson, GK
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02) : 344 - 351
  • [10] Homograft insertion for pulmonary regurgitation after repair of tetralogy of Fallot improves cardiorespiratory exercise performance
    Eyskens, B
    Reybrouck, T
    Bogaert, J
    Dymarkowsky, S
    Daenen, W
    Dumoulin, M
    Gewillig, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (02) : 221 - 225