Reduction of respiratory motion artifacts in transverse relaxation rate (R2) images of the liver

被引:14
作者
Clark, PR [1 ]
Chua-anusorn, W [1 ]
St Pierre, TG [1 ]
机构
[1] Univ Western Australia, Sch Phys, Perth, WA 6009, Australia
基金
英国医学研究理事会;
关键词
magnetic resonance images; motion artifact; abdomen; liver; transverse relaxation rate; iron;
D O I
10.1016/j.compmedimag.2003.06.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An empirical motion artifact suppression technique has been developed to reduce the respiratory motion artifacts in axial single spin-echo magnetic resonance (MR) images of the liver post-acquisition. The correction scheme is based on the observation that the dominant motion artifacts within abdominal MR images are ghosts that follow the profile and signal intensity of high signal intensity boundaries, such as those for the subcutaneous fat along the anterior abdominal wall. The technique is applied to the reduction of respiratory motion artifacts in a spin echo image series of the liver of an iron-loaded patient and of a manganese chloride phantom subject to respiratory motion. Subsequent improvements to transverse relaxation rate (R-2) image analysis are then demonstrated on the motion-corrected spin echo images, illustrating the utility of the technique for application in the R-2 image-based measurement and mapping of liver iron concentration. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 29 条
[1]   UNEVEN HEPATIC IRON AND PHOSPHORUS DISTRIBUTION IN BETA-THALASSEMIA [J].
AMBU, R ;
CRISPONI, G ;
SCIOT, R ;
VANEYKEN, P ;
PARODO, G ;
IANNELLI, S ;
MARONGIU, F ;
SILVAGNI, R ;
NURCHI, V ;
COSTA, V ;
FAA, G ;
DESMET, VJ .
JOURNAL OF HEPATOLOGY, 1995, 23 (05) :544-549
[2]  
Atkinson D, 1999, MAGNET RESON MED, V41, P163, DOI 10.1002/(SICI)1522-2594(199901)41:1<163::AID-MRM23>3.0.CO
[3]  
2-9
[4]   Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion [J].
Atkinson, D ;
Hill, DLG ;
Stoyle, PNR ;
Summers, PE ;
Keevil, SF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :903-910
[5]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[6]   Quantitative mapping of transverse relaxivity (1/T2) in hepatic iron overload:: a single spin-echo imaging methodology [J].
Clark, PR ;
St Pierre, TG .
MAGNETIC RESONANCE IMAGING, 2000, 18 (04) :431-438
[7]   Bi-exponential proton transverse relaxation rate (R2) image analysis using RF field intensity-weighted spin density projection:: potential for R2 measurement of iron-loaded liver [J].
Clark, PR ;
Chua-anusorn, W ;
St Pierre, TG .
MAGNETIC RESONANCE IMAGING, 2003, 21 (05) :519-530
[8]   Proton transverse relaxation rate (R2) images of iron-loaded liver tissuepping local tissue iron concentrations with MRI [J].
Clark, PR ;
Chua-anusorn, W ;
St Pierre, TG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :572-575
[9]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[10]  
Emond MJ, 1999, CLIN CHEM, V45, P340