Stenting for the treatment of high-grade intracranial stenoses
被引:18
作者:
论文数: 引用数:
h-index:
机构:
Lanfranconi, S.
[1
,2
]
Bersano, A.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Univ Milan, Ctr Dino Ferrari, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Bersano, A.
[1
,2
]
Branca, V.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Dept Diagnost & Intervent Neuroradiol, Fdn IRCCS CA Granda, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Branca, V.
[3
]
Ballabio, E.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Univ Milan, Ctr Dino Ferrari, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Ballabio, E.
[1
,2
]
Isalberti, M.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Dept Diagnost & Intervent Neuroradiol, Fdn IRCCS CA Granda, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Isalberti, M.
[3
]
Papa, R.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Dept Diagnost & Intervent Neuroradiol, Fdn IRCCS CA Granda, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Papa, R.
[3
]
Candelise, L.
论文数: 0引用数: 0
h-index: 0
机构:
Osped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Univ Milan, Ctr Dino Ferrari, Milan, ItalyOsped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
Candelise, L.
[1
,2
]
机构:
[1] Osped Maggiore Policlin, Neurol Unit, Fdn IRCCS CA Granda, Milan, Italy
[2] Univ Milan, Ctr Dino Ferrari, Milan, Italy
[3] Osped Maggiore Policlin, Dept Diagnost & Intervent Neuroradiol, Fdn IRCCS CA Granda, Milan, Italy
To date, evidence to recommend endovascular treatment in patients with intracranial stenoses is lacking. Recently, the introduction of self-expanding stents (Wingspan Stent System) aroused considerable expectations in their employ for stroke prevention. We report a single-center experience of percutaneous transluminal angioplasty and stenting in a series of consecutive patients with intracranial stenoses and compare the safety and performance of balloon-mounted stents versus self-expanding stent systems (Wingspan). Thirty-four patients with 39 severe (>70%) intracranial stenoses were treated during a 6-year period. An independent stroke neurologist collected data about intra and periprocedural complications and short-term outcome. We considered as endpoint measures (1) any 30-day stroke or death (2) any major 30-day complication and (3) procedure technical success. Technical success was achieved in all patients. No vessel dissection or ruptures were observed. The 30-day stroke/death rate was 17.9%. Five ischemic strokes in the territory of treated vessels and two intracranial hemorrhages occurred respectively within 24 h and 5 days after endovascular treatment. Three (17.6%) patients of Wingspan treated group and four (18.2%) of the patients treated with different stent systems had unfavorable outcome. Our study confirms that endovascular treatment can be performed with a high technical success rate, even though the safety of these devices has still to be demonstrated.