Direct Plate-Reader Measurement of Nitric Oxide Released from Hypoxic Erythrocytes Flowing through a Microfluidic Device

被引:33
作者
Halpin, Stephen T. [1 ]
Spence, Dana M. [1 ]
机构
[1] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
TITER PLATE; SINGLE-CELL; MICROCHIP; SYSTEMS; ARRAY; POLY(DIMETHYLSILOXANE); ELECTROPHORESIS; POLYMER; POLYCARBONATE; PURIFICATION;
D O I
10.1021/ac101130s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ability to perform a fluorescence-based quantitative determination of a biologically important analyte directly released from mammalian cells using a standard micro-titer plate reader to measure wells integrated into a microfluidic device is reported. Specifically, the amount of nitric oxide (NO) released from flowing erythrocytes (ERYs) exposed to a hypoxic buffer is measured using a fluorescein-based probe. The ERYs are pumped through channels in one layer of the poly(dimethylsiloxane) (PDMS) device; as these cells release NO, it flows through a porous polycarbonate membrane to the probe. The device is then placed into a standard micro-titer plate reader for measurement, with the entire calibration and analyte determination occurring simultaneously. Using this method, NO release from hypoxic ERYs was determined to be 6.9 +/- 1.8 mu M, a significantly increased value in comparison to that from normoxic ERYs of 0.60 +/- 0.04 mu M (p < 0.001, n = 4 rabbits). Furthermore, the reproducibility (reported as a %RSD) of measuring fluorescence standards was 3.5%. Detection limits, dynamic range, and optimal membrane pore diameters are also reported. This device enables the use of a standard high-throughput tool (the plate reader) to measure analytes in a microfluidic device, the ability to improve the quantitative determination of a relatively unstable molecule (NO), and the incorporation of a flow component and blood constituent into a system that can be combined with micro-titer plate technology.
引用
收藏
页码:7492 / 7497
页数:6
相关论文
共 39 条
[1]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[2]  
2-7
[3]   Patterned deposition of cells and proteins onto surfaces by using three-dimensional microfluidic systems [J].
Chiu, DT ;
Jeon, NL ;
Huang, S ;
Kane, RS ;
Wargo, CJ ;
Choi, IS ;
Ingber, DE ;
Whitesides, GM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (06) :2408-2413
[4]   A 96-well microplate incorporating a replica molded microfluidic network integrated with photonic crystal biosensors for high throughput kinetic biomolecular interaction analysis [J].
Choi, Charles J. ;
Cunningham, Brian T. .
LAB ON A CHIP, 2007, 7 (05) :550-556
[5]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[6]  
2-7
[7]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[8]   A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability [J].
Easley, Christopher J. ;
Karlinsey, James M. ;
Bienvenue, Joan M. ;
Legendre, Lindsay A. ;
Roper, Michael G. ;
Feldman, Sanford H. ;
Hughes, Molly A. ;
Hewlett, Erik L. ;
Merkel, Tod J. ;
Ferrance, Jerome P. ;
Landers, James P. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (51) :19272-19277
[9]   Cells on chips [J].
El-Ali, Jamil ;
Sorger, Peter K. ;
Jensen, Klavs F. .
NATURE, 2006, 442 (7101) :403-411
[10]   Addressing a vascular endothelium array with blood components using underlying microfluidic channels [J].
Genes, Luiza I. ;
Tolan, Nicole V. ;
Hulvey, Matthew K. ;
Martin, R. Scott ;
Spence, Dana M. .
LAB ON A CHIP, 2007, 7 (10) :1256-1259