Mechanics of (Xe)N atomic chains under STM manipulation -: art. no. 085415

被引:24
作者
Bouju, X [1 ]
Joachim, C
Girard, C
Tang, H
机构
[1] Univ Franche Comte, Phys Mol Lab, CNRS, UMR 6624, F-25030 Besancon, France
[2] Ctr Elaborat Mat & Etud Struct, CNRS, UPR 8011, F-31055 Toulouse 4, France
关键词
D O I
10.1103/PhysRevB.63.085415
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The mechanical behavior of short atomic chains under the action of a scanning tunneling microscope (STM) tip is investigated from computerized simulations. The calculation of the constrained atomic positions is performed with a molecular-dynamics approach. The system studied consists of N(1 less than or equal toN less than or equal to5) xenon atoms located in the Cu(110)-surface/tetragonal Cu-tip interface. The tunneling current calculation is based on the elastic scattering quantum chemistry method. The combination of these two descriptions (electric and mechanical) allows the behavior of the adsorbates to be described precisely. In particular, when working in the operational constant current mode. our numerical scheme behaves as a realistic virtual STM that allows an accurate prediction of the intrinsic mechanisms involved in similar experiments. In a first stage, for a single atom we present a diagram summarizing the different possible mechanisms versus the different initial conditions. By adding a second adsorbate, we establish a relation between the adsorbate spacing and the evolution of the tip trajectory [the so-called feedback loop signal (FLS)]. Finally, we present a discussion on the shape of such FLS signals when a linear chain composed of five Xe atoms is laterally pushed by the tip. The extraction of quantitative information on the adsorbate configurations during the manipulation is also addressed.
引用
收藏
页数:11
相关论文
共 43 条
[1]   Imaging in scanning tunneling microscopy and its relationship with surface roughness [J].
Aguilar, M ;
Oliva, AI ;
Anguiano, E .
EUROPHYSICS LETTERS, 1999, 46 (04) :442-447
[2]   Optimal conditions for imaging in scanning tunneling microscopy: Theory [J].
Anguiano, E ;
Oliva, AI ;
Aguilar, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3867-3874
[3]  
[Anonymous], COMMUNICATION
[4]   Basic steps of lateral manipulation of single atoms and diatomic clusters with a scanning tunneling microscope tip [J].
Bartels, L ;
Meyer, G ;
Rieder, KH .
PHYSICAL REVIEW LETTERS, 1997, 79 (04) :697-700
[5]   Basic steps involved in the lateral manipulation of single CO molecules and rows of CO molecules [J].
Bartels, L ;
Meyer, G ;
Rieder, KH .
CHEMICAL PHYSICS LETTERS, 1997, 273 (5-6) :371-375
[6]   Atomic hop-scotch: different manipulation modes of single Cu atoms on Cu(111) [J].
Bartels, L ;
Meyer, G ;
Rieder, KH .
CHEMICAL PHYSICS LETTERS, 1998, 285 (3-4) :284-287
[7]   Reversed surface corrugation in STM images on Au(111) by field-induced lateral motion of adsorbed molecules [J].
Böhringer, M ;
Morgenstern, K ;
Schneider, WD ;
Berndt, R .
SURFACE SCIENCE, 2000, 457 (1-2) :37-50
[8]   Scanning tunneling microscope-induced molecular motion and its effect on the image formation [J].
Bohringer, M ;
Schneider, WD ;
Berndt, R .
SURFACE SCIENCE, 1998, 408 (1-3) :72-85
[9]   Adsorption site determination of PTCDA on Ag(110) by manipulation of adatoms [J].
Böhringer, M ;
Schneider, WD ;
Glöckler, K ;
Umbach, E ;
Berndt, R .
SURFACE SCIENCE, 1998, 419 (01) :L95-L99
[10]   van der Waals atomic trap in a scanning-tunneling-microscope junction: Tip shape, dynamical effects, and tunnel current signatures [J].
Bouju, X ;
Girard, C ;
Tang, H ;
Joachim, C ;
Pizzagalli, L .
PHYSICAL REVIEW B, 1997, 55 (24) :16498-16506