Evaluation of a novel method of noise reduction using computer-simulated mammograms

被引:14
作者
Tischenko, O
Hoeschen, C
Dance, DR
Hunt, RA
Maidment, ADA
Bakic, PR
机构
[1] Univ Hosp Magdeburg, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
[2] GSF, Natl Ctr Environm & Hlth, Inst Radiat Protect, Working Grp Med Phys, D-85764 Neuherberg, Germany
[3] Royal Marsden NHS Fdn Trust London, Dept Phys, London SW3 6JJ, England
[4] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
关键词
D O I
10.1093/rpd/nch517
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
A novel method of noise reduction has been tested for mammography using computer-simulated images for which the truth is known exactly. This method is based on comparing two images. The images are compared at different scales, using a cross-correlation function as a measure of similarity to define the image modifications in the wavelet domain. The computer-simulated images were calculated for noise-free primary radiation using a quasi-realistic voxel phantom. Two images corresponding to slightly different geometry were produced. Gaussian noise was added with certain properties to simulate quantum noise. The added noise could be reduced by > 70% using the proposed method without any noticeable corruption of the structures. It is possible to save 50% dose in mammography by producing two images (each 25% of the dose for a standard mammogram). Additionally, a reduction of the anatomical noise and, therefore, better detection rates of breast cancer in mammography are possible.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 5 条
[1]
Mammogram synthesis using a 3D simulation. II. Evaluation of synthetic mammogram texture [J].
Bakic, PR ;
Albert, M ;
Brzakovic, D ;
Maidment, ADA .
MEDICAL PHYSICS, 2002, 29 (09) :2140-2151
[2]
Comparison of technical and anatomical noise in digital thorax X-ray images [J].
Hoeschen, C ;
Tischenko, O ;
Buhr, E ;
Illers, H .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :75-80
[3]
Calculation of the properties of digital mammograms using a computer simulation [J].
Hunt, RA ;
Dance, DR ;
Bakic, PR ;
Maidment, ADA ;
Sandborg, M ;
Ullman, G ;
Carlsson, GA .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :395-398
[4]
Reduction of anatomical noise in medical X-ray images [J].
Tischenko, O ;
Hoeschen, C ;
Buhr, E .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :69-74
[5]
Measurement of the noise components in the medical X-ray intensity pattern due to overlaying, nonrecognizable structures [J].
Tischenko, O ;
Hoeschen, C ;
Effenberger, O ;
Reissberg, S ;
Buhr, E ;
Döhring, W .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :422-432