Comparison of technical and anatomical noise in digital thorax X-ray images

被引:18
作者
Hoeschen, C
Tischenko, O
Buhr, E
Illers, H
机构
[1] Univ Hosp Magdeburg, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
[3] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1093/rpd/nch543
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Former studies by Hoeschen and Buhr indicated a higher total noise in a thorax image than expected from technical noise, i.e. quantum and detector noise. This difference results from the overlay of many small anatomical structures along the X-ray beam, which leads to a noise-like appearance without distinguishable structures in the projected image. A method is proposed to quantitatively determine this 'anatomical noise' component, which is not to be confused with the anatomical background (e.g. ribs). This specific anatomical noise pattern in a radiograph changes completely when the imaging geometry changes because different small anatomical structures contribute to the projected image. Therefore, two images are taken using slightly different exposure geometry, and a correlation analysis based on wavelet transforms allows to determining the uncorrelated noise components. Since the technical noise also differs from image to image, which makes it difficult to separate the anatomical noise, images of a lung phantom were produced on a low-sensitive industrial X-ray film using high-exposure levels. From these results, the anatomical noise level in real clinical thorax radiographs using realistic exposure levels is predicted using the general dose dependence described in the paper text and compared with the quantum and detector noise level of an indirect flat-panel detector system. For consistency testing, the same lung phantom was imaged with the same digital flat-panel detector and the total image noise including anatomical noise is determined. The results show that the relative portion of anatomical noise may exceed the technical noise level. Anatomical noise is an important contributor to the total image noise and, therefore, impedes the recognition of anatomical structures.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 15 条
[1]
[Anonymous], 1993, Ten Lectures of Wavelets
[2]
[Anonymous], 1999, WAVELET TOUR SIGNAL
[3]
BOCHUD FO, 1995, P SOC PHOTO-OPT INS, V2436, P156, DOI 10.1117/12.206845
[4]
BOCHUD FO, 1999, P SOC PHOTO-OPT INS, V3663, P283
[5]
Visual signal detectability with two noise components: Anomalous masking effects [J].
Burgess, AE ;
Li, X ;
Abbey, CK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (09) :2420-2442
[6]
IDEAL SPATIAL ADAPTATION BY WAVELET SHRINKAGE [J].
DONOHO, DL ;
JOHNSTONE, IM .
BIOMETRIKA, 1994, 81 (03) :425-455
[7]
High spatial resolution measurement of the X-ray intensity pattern in a radiograph of the thorax [J].
Hoeschen, C ;
Buhr, E ;
Döhring, W .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :432-443
[8]
Measurement of correlated noise in images of computed radiography systems and its influence on the detective quantum efficiency [J].
Illers, H ;
Vandenbroucke, D ;
Buhr, E .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :639-647
[9]
Measurement of the Detective Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1 [J].
Illers, H ;
Buhr, E ;
Bergmann, D ;
Hoeschen, C .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :177-187
[10]
International Electrotechnical Commission, 2003, MED EL EQ CHAR DIG 1