Effects of Image Characteristics on Performance of Tumor Delineation Methods: A Test-Retest Assessment

被引:58
作者
Cheebsumon, Patsuree [1 ,3 ]
van Velden, Floris H. P. [1 ,3 ]
Yaqub, Maqsood [1 ,3 ]
Frings, Virginie [1 ,3 ]
de Langen, Adrianus J. [2 ]
Hoekstra, Otto S. [1 ,3 ]
Lammertsma, Adriaan A. [1 ,3 ]
Boellaard, Ronald [1 ,3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Nucl Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Pulm Dis, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, PET Res, NL-1007 MB Amsterdam, Netherlands
关键词
(semi-)automatic tumor delineation; (18)F-FDG; (18)F-FLT; PET; test-retest variability; CELL LUNG-CANCER; FDG-PET; VOLUME MEASUREMENTS; F-18-FDG; REPRODUCIBILITY; RADIOTHERAPY; VALIDATION;
D O I
10.2967/jnumed.111.088914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET can be used to monitor response during chemotherapy and assess biologic target volumes for radiotherapy. Previous simulation studies have shown that the performance of various automatic or semiautomatic tumor delineation methods depends on image characteristics. The purpose of this study was to assess test-retest variability of tumor delineation methods, with emphasis on the effects of several image characteristics (e.g., resolution and contrast). Methods: Baseline test-retest data from 19 non-small cell lung cancer patients were obtained using (18)F-FDG (n = 10) and 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) (n = 9). Images were reconstructed with varying spatial resolution and contrast. Six different types of tumor delineation methods, based on various thresholds or on a gradient, were applied to all datasets. Test-retest variability of metabolic volume and standardized uptake value (SUV) was determined. Results: For both tracers, size of metabolic volume and test-retest variability of both metabolic volume and SUV were affected by the image characteristics and tumor delineation method used. The median volume test-retest variability ranged from 8.3% to 23% and from 7.4% to 29% for (18)F-FDG and (18)F-FLT, respectively. For all image characteristics studied, larger differences (<= 10-fold higher) were seen in test-retest variability of metabolic volume than in SUV. Conclusion: Test-retest variability of both metabolic volume and SUV varied with tumor delineation method, radiotracer, and image characteristics. The results indicate that a careful optimization of imaging and delineation method parameters is needed when metabolic volume is used, for example, as a response assessment parameter.
引用
收藏
页码:1550 / 1558
页数:9
相关论文
共 20 条
[1]  
Boellaard R, 2004, J NUCL MED, V45, P1519
[2]  
Boellaard R, 2001, J NUCL MED, V42, P808
[3]   FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0 [J].
Boellaard, Ronald ;
O'Doherty, Mike J. ;
Weber, Wolfgang A. ;
Mottaghy, Felix M. ;
Lonsdale, Markus N. ;
Stroobants, Sigrid G. ;
Oyen, Wim J. G. ;
Kotzerke, Joerg ;
Hoekstra, Otto S. ;
Pruim, Jan ;
Marsden, Paul K. ;
Tatsch, Klaus ;
Hoekstra, Corneline J. ;
Visser, Eric P. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee M. ;
Comans, Emile F. I. ;
Lammertsma, Adriaan A. ;
Paans, Anne M. ;
Willemsen, Antoon T. ;
Beyer, Thomas ;
Bockisch, Andreas ;
Schaefer-Prokop, Cornelia ;
Delbeke, Dominique ;
Baum, Richard P. ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) :181-200
[4]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[5]  
Brix G, 1997, J NUCL MED, V38, P1614
[6]   Clinical relevance of imaging proliferative activity in lung nodules [J].
Buck, AK ;
Hetzel, M ;
Schirrmeister, H ;
Halter, G ;
Möller, P ;
Kratochwil, C ;
Wahl, A ;
Glatting, G ;
Mottaghy, FM ;
Mattfeldt, T ;
Neumaier, B ;
Reske, SN .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (05) :525-533
[7]  
Cheebsumon P, 2010, EUR J NUCL MED MOL I, V37, pS261
[8]   Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250
[9]   Predictive and prognostic value of FDG-PET in nonsmall-cell lung cancer - A systematic review [J].
de Geus-Oei, Lioe-Fee ;
van der Heijden, Henricus F. M. ;
Corstens, Frans H. M. ;
Oyen, Wirn J. G. .
CANCER, 2007, 110 (08) :1654-1664
[10]   Reproducibility of quantitative 18F-3'-deoxy-3'-fluorothymidine measurements using positron emission tomography [J].
de Langen, Adrianus J. ;
Klabbers, Bianca ;
Lubberink, Mark ;
Boellaard, Ronald ;
Spreeuwenberg, Marieke D. ;
Slotman, Ben J. ;
de Bree, Remco ;
Smit, Egbert F. ;
Hoekstra, Otto S. ;
Lammertsma, Adriaan A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (03) :389-395