Closed-loop performance monitoring in the presence of system changes and disturbances

被引:35
作者
Gustafsson, F [1 ]
Graebe, SF
机构
[1] Linkoping Univ, Dept Elect Engn, S-58183 Linkoping, Sweden
[2] Univ Newcastle, Dept Elect & Comp Engn, Newcastle, NSW 2308, Australia
[3] Univ Newcastle, Ctr Ind Control Sci, Newcastle, NSW 2308, Australia
[4] OMV, A-2320 Schwechat, Austria
关键词
performance monitoring; fault detection; monitoring feedback loops;
D O I
10.1016/S0005-1098(98)00078-8
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper addresses issues in closed-loop performance monitoring. Particular attention is paid to detecting whether an observed deviation from nominal performance is due to a disturbance or due to a control relevant system change. This is achieved by introducing a novel performance measure that allows feasible application of a standard CUSUM change detector. The paper includes explicit results on the risk of mistaking a disturbance for a system change. The algorithm has been implemented in real time on a DSP and evaluated on a DC motor. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1311 / 1326
页数:16
相关论文
共 20 条
[1]  
Astrom K. J., 1995, Adaptive Control
[2]  
Basseville M, 1993, DETECTION ABRUPT CHA
[3]  
*DSPACE, 1983, REAL TIM INT
[4]  
ERIKSSON PG, 1994, IEEE C CONTR APPL GL, V2, P1029
[5]   ROBUST AND ADAPTIVE-CONTROL OF AN UNKNOWN PLANT - A BENCHMARK OF NEW FORMAT [J].
GRAEBE, SF .
AUTOMATICA, 1994, 30 (04) :567-575
[6]  
Gustafsson F., 1995, Proceedings of the Third European Control Conference. ECC 95, P453
[7]   ASSESSMENT OF CONTROL LOOP PERFORMANCE [J].
HARRIS, TJ .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1989, 67 (05) :856-861
[8]   ROBUST ADAPTIVE-CONTROL OF A TIME-VARYING PROCESS USING PARALLEL RECURSIVE ESTIMATORS [J].
HECKER, O ;
KNAPP, T ;
ISERMANN, R .
AUTOMATICA, 1994, 30 (04) :599-604
[9]  
KERESTECIOGLU F, 1991, EUR CONTROL C GRENOB, P321
[10]  
*MATLAB, 1993, SIM US GUID