Mr digital subtraction angiography with asymmetric echo acquisition and complex subtraction: Improved lumen and stenosis visualization

被引:8
作者
Hoogeveen, RM [1 ]
Bakker, CJG [1 ]
Viergever, MA [1 ]
机构
[1] Univ Utrecht Hosp, Dept Radiol, Image Sci Inst, Utrecht, Netherlands
关键词
MR-DSA; asymmetric echo; complex subtraction; stenosis;
D O I
10.1016/S0730-725X(98)00164-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of complex subtraction in dynamic thick slab 2D MR digital subtraction angiography (MR-DSA) has been shown to eliminate partial volume effects, which are present if vessels cover a small fraction of the 2D slab. However, spin dephasing still results in a poor visualization of areas with complex flow. In this paper, it is shown that this can be overcome by using asymmetric echo (ASE) acquisition combined with complex subtraction. It is proven that an ASE acquisition does not destroy information necessary for complex subtraction if the subtraction is performed in k-space, As a consequence, the subtraction reconstruction is as reliable as the magnitude reconstruction of a single ASE data set,Experiments with ASE and complex subtraction show that Bow voids near stenoses disappear, that the signal-to-noise ratio is improved and that temporal resolution is increased. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:305 / 311
页数:7
相关论文
共 15 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]  
CUPPEN J, 1987, Magnetic Resonance Imaging, V5, P526, DOI 10.1016/0730-725X(87)90402-4
[3]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[4]  
EVANS AJ, 1993, AM J NEURORADIOL, V14, P721
[5]   HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG [J].
FEINBERG, DA ;
HALE, JD ;
WATTS, JC ;
KAUFMAN, L ;
MARK, A .
RADIOLOGY, 1986, 161 (02) :527-531
[6]   MECHANISMS OF SIGNAL LOSS IN MAGNETIC-RESONANCE-IMAGING OF STENOSES [J].
GATENBY, JC ;
MCCAULEY, TR ;
GORE, JC .
MEDICAL PHYSICS, 1993, 20 (04) :1049-1057
[7]   A FAST, ITERATIVE, PARTIAL-FOURIER TECHNIQUE CAPABLE OF LOCAL PHASE RECOVERY [J].
HAACKE, EM ;
LINDSKOG, ED ;
LIN, W .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01) :126-145
[8]   Time-resolved projection angiography after bolus injection of contrast agent [J].
Hennig, J ;
Scheffler, K ;
Laubenberger, J ;
Strecker, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :341-345
[9]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[10]  
LINDSKOG E, 1989, 8TH SOC MAGN RES MED, P363