Electrokinetic Analyte Transport Assay for α-fetoprotein immunoassay integrates mixing, reaction and separation on-chip

被引:54
作者
Kawabata, Tomohisa [2 ]
Wada, Henry G. [2 ]
Watanabe, Mitsuo [1 ]
Satomura, Shinji [1 ]
机构
[1] Wako Pure Chem Ind, New Diagnost Business & Technol Dev Dept, Amagasaki, Hyogo 6610963, Japan
[2] Wako Pure Chem Ind, New Diagnost Business & Technol Dev Dept, Mt View R&D Ctr, Mountain View, CA USA
关键词
alpha-fetoprotein; high sensitivity; immunoassay; isotachophoresis; on-chip;
D O I
10.1002/elps.200700898
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and highly sensitive CE immunoassay method integrating mixing, reaction, separation, and detection on-chip is described for the measurement of alpha-fetoprotein (AFP), a liver cancer marker in blood. Antibody-binding reagents, consisting of 245-bp DNA coupled anti-AFP WA1 antibody (DNA-WA1) and HiLyte dye-labeled anti-AFP WA2 antibody (HiLyte-WA2), and AFP-containing sample were filled into adjacent zones of a chip channel defined by the laminar flow lines of the microfluidic device using pressure-driven flow. The channel geometry was thus used to quantitatively aliquot the reagents and sample into the chip. DNA-WA1 was electrokinetically concentrated in the channel and sequentially transported through the AFP-sample zone and HiLyte-WA2 zone by ITP in such a manner that the AFP sandwich immune complex formation took place in the sample and HiLyte-WA2 zones. The sandwich AFP immune complex was then detected by LIF after CGE in a separation channel that was arranged downstream of the reaction channel. AFP was detected within 136 s with a detection sensitivity of 5 pM. The on-chip immunoassay described here, applying ITP concentration, in-channel reaction, and CGE separation, has the potential of providing a rapid and sensitive method for both clinical and research applications.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 33 条
[1]   Protein microchips: Use for immunoassay and enzymatic reactions [J].
Arenkov, P ;
Kukhtin, A ;
Gemmell, A ;
Voloshchuk, S ;
Chupeeva, V ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) :123-131
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   ULTRAMICRO ENZYME ASSAYS IN A CAPILLARY ELECTROPHORETIC SYSTEM [J].
BAO, JM ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :217-224
[4]  
Burke BJ, 2001, ELECTROPHORESIS, V22, P3744, DOI 10.1002/1522-2683(200109)22:17<3744::AID-ELPS3744>3.0.CO
[5]  
2-7
[6]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[7]  
Chiem NH, 1998, CLIN CHEM, V44, P591
[8]   A microchip-based enzyme assay for protein kinase A [J].
Cohen, CB ;
Chin-Dixon, E ;
Jeong, S ;
Nikiforov, TT .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (01) :89-97
[9]  
COOK DB, 1993, CLIN CHEM, V39, P965
[10]   α-fetoprotein and ultrasonography screening for hepatocellular carcinoma [J].
Daniele, B ;
Bencivenga, A ;
Megna, AS ;
Tinessa, V .
GASTROENTEROLOGY, 2004, 127 (05) :S108-S112