Experimental evaluation of lesion prediction modelling in the presence of cavitation bubbles: intended for high-intensity focused ultrasound prostate treatment

被引:64
作者
Curiel, L [1 ]
Chavrier, F [1 ]
Gignoux, B [1 ]
Pichardo, S [1 ]
Chesnais, S [1 ]
Chapelon, JY [1 ]
机构
[1] INSERM, U556, F-69008 Lyon, France
关键词
ultrasound surgery; high-intensity focused ultrasound; cavitation; lesion modelling; lesion prediction;
D O I
10.1007/BF02351010
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The accuracy of high-intensity focused ultrasound (HIFU) lesion prediction modelling was evaluated for a truncated spherical transducer designed for prostate cancer treatment. The modelling adapted the bio heat transfer equation (BHTE) to take into account the activity of cavitation bubbles generated during HIFU exposure. This modelling was used to predict the lesions produced by three different transducer geometries: fixed-focus, concentric-ring and 1.5D phased-array. Lesions were predicted for different ultrasound exposure conditions close to those used in prostate cancer treatment. Twenty-one in vitro and nine in vitro experiments were performed on pig liver to validate the accuracy of the predictions. A good match was found between the predicted and experimental lesion shapes. Lesion dimensions (maximum depth and length, area at the centre of the lesion or central surface area) were measured on experimental and predicted lesions. The central surface area was predicted by the model with a range of error of 0.15-6.5% for in vitro tests and 0.97-9% in vivo. For comparison, BHTE without bubbles had a range of error of 0.4-55.5% (in vitro) and 9-25.5% (in vivo). The model should be accurate enough to predict HIFU lesions under ultrasound exposure conditions used in prostate cancer treatment.
引用
收藏
页码:44 / 54
页数:11
相关论文
共 37 条
[1]   EFFECTS OF PHYSICAL PARAMETERS ON HIGH-TEMPERATURE ULTRASOUND HYPERTHERMIA [J].
BILLARD, BE ;
HYNYNEN, K ;
ROEMER, RB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (04) :409-420
[2]   A new high intensity focused ultrasound applicator for surgical applications [J].
Brentnall, MD ;
Martin, RW ;
Vaezy, S ;
Kaczkowski, P ;
Forster, F ;
Crum, L .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :53-63
[3]   ACOUSTIC PROPERTIES OF LESIONS GENERATED WITH AN ULTRASOUND THERAPY SYSTEM [J].
BUSH, NL ;
RIVENS, I ;
TERHAAR, GR ;
BAMBER, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :789-801
[4]  
Chapelon J Y, 1999, Eur J Ultrasound, V9, P31, DOI 10.1016/S0929-8266(99)00005-1
[5]  
CHAPELON JY, 1990, IEEE ULTR S P, V2, P1653
[6]  
CHAPELON JY, 1993, IEEE ULTR S, V2, P1211
[7]  
CHAPELON JY, 1991, IEEE ULTR S P, V2, P1357
[8]  
CHAPELON JY, 2001, INT J ACOUSTICS, V1, P100
[9]  
Chato JC, 1990, FUNDAMENTALS BIOHEAT, P1
[10]   Modeling of high-intensity focused ultrasound-induced lesions in the presence of cavitation bubbles [J].
Chavrier, F ;
Chapelon, JY ;
Gelet, A ;
Cathignol, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (01) :432-440