Simultaneous PET-MRI:: a new approach for functional and morphological imaging

被引:715
作者
Judenhofer, Martin S. [1 ]
Wehrl, Hans F. [1 ]
Newport, Danny F. [2 ]
Catana, Ciprian [3 ]
Siegel, Stefan B. [2 ]
Becker, Markus [4 ]
Thielscher, Axel [5 ]
Kneilling, Manfred [6 ]
Lichy, Matthias P. [1 ]
Eichner, Martin [7 ]
Klingel, Karin [8 ]
Reischl, Gerald [9 ]
Widmaier, Stefan [4 ]
Roecken, Martin [6 ]
Nutt, Robert E. [2 ]
Machulla, Hans-Juergen [9 ]
Uludag, Kamil [5 ]
Cherry, Simon R. [3 ]
Claussen, Claus D. [1 ]
Pichler, Bernd J. [1 ]
机构
[1] Univ Tubingen, Dept Radiol, Lab Preclin Imaging & Imaging Tech Werner Siemens, D-72076 Tubingen, Germany
[2] Siemens Preclin Solut, Knoxville, TN 37932 USA
[3] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[4] Bruker BioSpin MRI GmbH, D-76275 Ettingen, Germany
[5] Max Planck Inst Biol Cybernet, D-72076 Tubingen, Germany
[6] Univ Tubingen, Dermatol Clin, D-72076 Tubingen, Germany
[7] Univ Tubingen, Dept Med Biometry, D-72070 Tubingen, Germany
[8] Univ Tubingen, Inst Pathol, Dept Mol Pathol, D-72076 Tubingen, Germany
[9] Univ Tubingen, PET Ctr, D-72076 Tubingen, Germany
关键词
D O I
10.1038/nm1700
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Noninvasive imaging at the molecular level is an emerging field in biomedical research. This paper introduces a new technology synergizing two leading imaging methodologies: positron emission tomography ( PET) and magnetic resonance imaging ( MRI). Although the value of PET lies in its high- sensitivity tracking of biomarkers in vivo, it lacks resolving morphology. MRI has lower sensitivity, but produces high soft- tissue contrast and provides spectroscopic information and functional MRI ( fMRI). We have developed a three- dimensional animal PET scanner that is built into a 7- T MRI. Our evaluations show that both modalities preserve their functionality, even when operated isochronously. With this combined imaging system, we simultaneously acquired functional and morphological PET- MRI data from living mice. PET- MRI provides a powerful tool for studying biology and pathology in preclinical research and has great potential for clinical applications. Combining fMRI and spectroscopy with PET paves the way for a new perspective in molecular imaging.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 31 条
[1]  
Catana C, 2006, J NUCL MED, V47, P1968
[2]  
Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
[3]   SYNTHESIS OF THE RACEMATE AND INDIVIDUAL ENANTIOMERS OF [C-11] METHYLPHENIDATE FOR STUDYING PRESYNAPTIC DOPAMINERGIC NEURON WITH POSITRON EMISSION TOMOGRAPHY [J].
DING, YS ;
SUGANO, Y ;
FOWLER, JS ;
SALATA, C .
JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1994, 34 (10) :989-997
[4]   Report on a multicenter fMRI quality assurance protocol [J].
Friedman, L ;
Glover, GH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (06) :827-839
[5]  
Garlick PB, 1997, NMR BIOMED, V10, P138, DOI 10.1002/(SICI)1099-1492(199705)10:3<138::AID-NBM474>3.0.CO
[6]  
2-H
[7]   Design of field-cycled magnetic resonance systems for small animal imaging [J].
Gilbert, K. M. ;
Handler, W. B. ;
Scholl, T. J. ;
Odegaard, J. W. ;
Chronik, B. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2825-2841
[8]   PET/MR images acquired with a compact MR-compatiable PET detector in a 7-T magnet [J].
Judenhofer, Martin S. ;
Catana, Ciprian ;
Swann, Brian K. ;
Siegel, Stefan B. ;
Jung, Wulf-Ingo ;
Nutt, Robert E. ;
Cherry, Simon R. ;
Claussen, Claus D. ;
Pichler, Bernd J. .
RADIOLOGY, 2007, 244 (03) :807-814
[9]   Development of a combined microPET®-MR system [J].
Lucas, A. J. ;
Hawkes, R. C. ;
Ansorge, R. E. ;
Williams, G. B. ;
Nutt, R. E. ;
Clark, J. C. ;
Fryer, T. A. ;
Carpenter, T. A. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (04) :337-341
[10]   Simultaneous PET and NMR [J].
Marsden, PK ;
Strul, D ;
Keevil, SF ;
Williams, SCR ;
Cash, D .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 :S53-S59