Peripheral nerve regeneration by microbraided poly(L-lactide-co-glycolide) biodegradable polymer fibers

被引:137
作者
Bini, TB [1 ]
Gao, SJ
Xu, XY
Wang, S
Ramakrishna, S
Leong, KW
机构
[1] Natl Univ Singapore, Bioengn Div, Dept Engn Mech, Singapore 119260, Singapore
[2] Natl Univ Singapore, Inst Mat Sci & Engn, Mol & Biomat Lab, Singapore 117602, Singapore
[3] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
关键词
microbraiding; PLGA biodegradable fibers; nerve guide conduits; nerve regeneration;
D O I
10.1002/jbm.a.20050
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tiny tubes with fiber architecture were developed by a novel method of fabrication upon introducing some modification to the microbraiding technique, to function as nerve guide conduit and the feasibility of in vivo nerve regeneration was investigated through several of these conduits. Poly(L-lactide-co-glycolide) (10:90) polymer fibers being biocompatible and biodegradable were used for the fabrication of the conduits. The microbraided nerve guide conduits (MNGCs) were characterized using scanning electron microscopy to study the surface morphology and fiber arrangement. Degradation tests were performed and the micrographs of the conduit showed that the degradation of the conduit is by fiber breakage indicating bulk hydrolysis of the polymer. Biological performances of the conduits were examined in the rat sciatic nerve model with a 12-mm gap. After implantation of the MNGC to the right sciatic nerve of the rat, there was no inflammatory response. One week after implantation, a thin tissue capsule was formed on the outer surface of the conduit, indicating good biological response of the conduit. Fibrin matrix cable formation was seen inside the MNGC after 1 week implantation. One month after implantation, 9 of 10 rats showed successful nerve regeneration. None of the implanted tubes showed tube breakage. The MNGCs were flexible, permeable, and showed no swelling apart from its other advantages. Thus, these new poly(L-lactide-co-glycolide) microbraided conduits can be effective aids for nerve regeneration and repair and may lead to clinical applications. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:286 / 295
页数:10
相关论文
共 42 条
[1]  
[Anonymous], 1998, FRONTIERS TISSUE ENG
[2]   A COLLAGEN-BASED NERVE GUIDE CONDUIT FOR PERIPHERAL-NERVE REPAIR - AN ELECTROPHYSIOLOGICAL STUDY OF NERVE REGENERATION IN RODENTS AND NONHUMAN-PRIMATES [J].
ARCHIBALD, SJ ;
KRARUP, C ;
SHEFNER, J ;
LI, ST ;
MADISON, RD .
JOURNAL OF COMPARATIVE NEUROLOGY, 1991, 306 (04) :685-696
[3]   Early peripheral nerve healing in collagen and silicone tube implants: Myofibroblasts and the cellular response [J].
Chamberlain, LJ ;
Yannas, IV ;
Arrizabalaga, A ;
Hsu, HP ;
Norregaard, TV ;
Spector, M .
BIOMATERIALS, 1998, 19 (15) :1393-1403
[4]   A NEW PLLA PCL COPOLYMER FOR NERVE REGENERATION [J].
DENDUNNEN, WFA ;
SCHAKENRAAD, JM ;
ZONDERVAN, GJ ;
PENNINGS, AJ ;
VANDERLEI, B ;
ROBINSON, PH .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (05) :521-525
[5]  
denDunnen WFA, 1996, J BIOMED MATER RES, V31, P105, DOI 10.1002/(SICI)1097-4636(199605)31:1<105::AID-JBM13>3.0.CO
[6]  
2-M
[7]   BIOLOGICAL PERFORMANCE OF A DEGRADABLE POLY(LACTIC ACID-EPSILON-CAPROLACTONE) NERVE GUIDE - INFLUENCE OF TUBE DIMENSIONS [J].
DENDUNNEN, WFA ;
VANDERLEI, B ;
ROBINSON, PH ;
HOLWERDA, A ;
PENNINGS, AJ ;
SCHAKENRAAD, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (06) :757-766
[8]   PHYSICOMECHANICAL PROPERTIES OF DEGRADABLE POLYMERS USED IN MEDICAL APPLICATIONS - A COMPARATIVE-STUDY [J].
ENGELBERG, I ;
KOHN, J .
BIOMATERIALS, 1991, 12 (03) :292-304
[9]   PERIPHERAL-NERVE REGENERATION [J].
FAWCETT, JW ;
KEYNES, RJ .
ANNUAL REVIEW OF NEUROSCIENCE, 1990, 13 :43-60
[10]   Sciatic nerve regeneration through venous or nervous grafts in the rat [J].
FoidartDessalle, M ;
Dubuisson, A ;
Lejeune, A ;
Severyns, A ;
Manassis, Y ;
Delree, P ;
Crielaard, JM ;
Bassleer, R ;
Lejeune, G .
EXPERIMENTAL NEUROLOGY, 1997, 148 (01) :236-246