Fabrication of fritless chromatographic microchips packed with conventional reversed-phase silica particles

被引:56
作者
Gaspar, Attila [1 ]
Piyasena, Menake E. [1 ]
Gomez, Frank A. [1 ]
机构
[1] Calif State Univ Los Angeles, Dept Chem & Biochem, Los Angeles, CA 90032 USA
关键词
D O I
10.1021/ac071106g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development and study of a disposable and inexpensive microfluidic chip, fabricated from poly(dimethylsiloxane) (PDMS) incorporating conventional chromatographic reversed-phase silica particles (C18) without the use of frits, permanent physical barriers, tapers, or restrictors. The packing of C18 modified silica particles into the microfluidic channels is made possible by the hydrophobic nature and excellent elasticity of PDMS. Keystone-, clamping-, and anchor-effects provide the stability and the compactness of the packing and attenuated wall-effects were observed.
引用
收藏
页码:7906 / 7909
页数:4
相关论文
共 16 条
[1]   An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases [J].
Ceriotti, L ;
de Rooij, NF ;
Verpoorte, E .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :639-647
[2]   On-chip chromatography: the last twenty years [J].
de Mello, A .
LAB ON A CHIP, 2002, 2 (03) :48N-54N
[3]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[4]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87
[5]   Magnetically controlled valve for flow manipulation in polymer microfluidic devices [J].
Gaspar, Attila ;
Piyasena, Menake E. ;
Daroczi, Lajos ;
Gomez, Frank A. .
MICROFLUIDICS AND NANOFLUIDICS, 2008, 4 (06) :525-531
[6]   Flow-induced deformation of shallow microfluidic channels [J].
Gervais, T ;
El-Ali, J ;
Günther, A ;
Jensen, KF .
LAB ON A CHIP, 2006, 6 (04) :500-507
[7]   Fabrication of nanocolumns for liquid chromatography [J].
He, B ;
Tait, N ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3790-3797
[8]   OPEN-CHANNEL ELECTROCHROMATOGRAPHY ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2369-2373
[9]   EFFECT OF COLUMN TO PARTICLE DIAMETER RATIO ON DISPERSION OF UNSORBED SOLUTES IN CHROMATOGRAPHY [J].
KNOX, JH ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1969, 41 (12) :1599-&
[10]   Tapers and restrictors for capillary electrochromatography and capillary electrochromatography mass spectrometry [J].
Lord, GA ;
Gordon, DB ;
Myers, P ;
King, BW .
JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (01) :9-16