Multiplexed analysis of biomarkers related to obesity and the metabolic syndrome in human plasma, using the luminex-100 system

被引:145
作者
Liu, MY
Xydakis, AM
Hoogeveen, RC
Jones, PH
Smith, EOB
Nelson, KW
Ballantyne, CM
机构
[1] Baylor Coll Med, Dept Med, Sect Atherosclerosis, Houston, TX 77030 USA
[2] Baylor Coll Med, Div Endocrinol Diabet & Metab, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Pediat, Sect Nutr, Houston, TX 77030 USA
[4] Methodist Hosp, Methodist Wellness Serv, Houston, TX 77030 USA
关键词
D O I
10.1373/clinchem.2004.047084
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 [基础医学];
摘要
Background: The complex pathology of disease has sparked the development of novel protein expression profiling techniques that require validation in clinical settings. This study focuses on multiplexed analyses of adipocytokines and biomarkers linked to the metabolic syndrome, diabetes, and cardiovascular disease. Methods: Multiplexed immunoassays using fluorescent microspheres and the Luminex-100 system were performed on plasma from 80 obese patients (40 with the metabolic syndrome) before and after 6-8 weeks of diet-induced weight loss. Leptin, insulin, C-peptide, monocyte chemoattractant protein-1 (MCP-1), eotaxin, interleukin-8 (IL-8), tumor necrosis factor-alpha (TNF-alpha), and IL-6 concentrations measured with multiplex panels from 3 different manufacturers were compared with results from commercial ELISAs. Detection limits and between- and within-run imprecision were determined for each analyte. Bland-Altman analysis was used to determine agreement between multiplexed immunoassays and ELISAs. Results: Correlation between the Luminex multiplexed assays and ELISAs was good for leptin (Linco), insulin (Linco), MCP-1 (Biosource and Upstate), and eotaxin (Biosource) with correlation coefficients of 0.711-0.895; fair for eotaxin (Upstate) and C-peptide (Linco) with correlation coefficients of 0.496-0.582; and poor for TNF-alpha, IL-8, and IL-6 (Linco, Biosource, Upstate, and R&D) with correlation coefficients of -0.107 to 0.318. Within- and between-run imprecision values for the multiplex method were generally < 15%. Relative changes in plasma leptin and insulin concentrations after diet-induced weight loss were similar whether assessed by multiplex assay or ELISA. Conclusion: Although this technology appears useful in clinical research studies, low assay sensitivity and poor correlations with conventional ELISA methods for some analytes with very low plasma concentrations should be considered when using the Luminex platform in clinical studies. (c) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:1102 / 1109
页数:8
相关论文
共 21 条
[1]
Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins [J].
Biagini, RE ;
Sammons, DL ;
Smith, JP ;
MacKenzie, BA ;
Striley, CAF ;
Semenova, V ;
Steward-Clark, E ;
Stamey, K ;
Freeman, AE ;
Quinn, CP ;
Snawder, JE .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (01) :50-55
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Impact of weight loss on the metabolic syndrome [J].
Case, CC ;
Jones, PH ;
Nelson, K ;
Smith, EO ;
Ballantyne, CM .
DIABETES OBESITY & METABOLISM, 2002, 4 (06) :407-414
[4]
Executive summary of the Third Report of the National Cholesterol Education Program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel III) [J].
Cleeman, JI ;
Grundy, SM ;
Becker, D ;
Clark, LT ;
Cooper, RS ;
Denke, MA ;
Howard, WJ ;
Hunninghake, DB ;
Illingworth, DR ;
Luepker, RV ;
McBride, P ;
McKenney, JM ;
Pasternak, RC ;
Stone, NJ ;
Van Horn, L ;
Brewer, HB ;
Ernst, ND ;
Gordon, D ;
Levy, D ;
Rifkind, B ;
Rossouw, JE ;
Savage, P ;
Haffner, SM ;
Orloff, DG ;
Proschan, MA ;
Schwartz, JS ;
Sempos, CT ;
Shero, ST ;
Murray, EZ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (19) :2486-2497
[5]
Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells [J].
de Jager, W ;
te Velthuis, H ;
Prakken, BJ ;
Kuis, W ;
Rijkers, GT .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) :133-139
[6]
Prevalence and trends in obesity among US adults, 1999-2000 [J].
Flegal, KM ;
Carroll, MD ;
Ogden, CL ;
Johnson, CL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (14) :1723-1727
[7]
Prevalence of the metabolic syndrome among US adults - Findings from the Third National Health and Nutrition Examination Survey [J].
Ford, ES ;
Giles, WH ;
Dietz, WH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (03) :356-359
[8]
OBESITY AS AN INDEPENDENT RISK FACTOR FOR CARDIOVASCULAR-DISEASE - A 26-YEAR FOLLOW-UP OF PARTICIPANTS IN THE FRAMINGHAM HEART-STUDY [J].
HUBERT, HB ;
FEINLEIB, M ;
MCNAMARA, PM ;
CASTELLI, WP .
CIRCULATION, 1983, 67 (05) :968-977
[9]
Cytokines as mediators for or effectors against rotavirus disease in children [J].
Jiang, B ;
Snipes-Magaldi, L ;
Dennehy, P ;
Keyserling, H ;
Holman, RC ;
Bresee, J ;
Gentsch, J ;
Glass, RI .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (06) :995-1001
[10]
Kaplan IV, 1999, CLIN CHEM, V45, P616